Running Individual Tests 4
The TDR Test
TDR Results Screen
When the TDR test is complete, the TDR results screen appears. Table
Table 4-5. Items on a TDR Results Screen (Twisted Pair Results)
Item
Pair
Distance
Description
The cable pair relevant to the results. Not shown for coaxial cable results.
The first distance is the measured distance from the test tool to the end of the cable. The second distance, if shown, is the distance from the test tool to the beginning of the largest anomaly that caused a reflection greater than the limit defined by the selected test standard.
Peak
#View Plot
The percentage of the test signal reflected at the peak of the anomaly.
Press to see a plot of the locations and reflection percentages of the impedance anomalies detected.
Note
It is possible for impedance anomalies to be detected when testing from one end of the cable, but not from the other end. This discrepancy is caused by attenuation of the signal reflections returning from the anomaly.
TDR Plot Screen
To view the TDR plot for a cable pair, use DUto highlight one of the pairs; then press #View Plot to see the plot screen for that pair. Figure