Fluke DSP-100, DSP-2000 user manual Autotest Report for Coaxial Cable

Models: DSP-2000 DSP-100

1 196
Download 196 pages 36.87 Kb
Page 75
Image 75

 

 

 

 

 

 

 

Autotest

3

 

 

 

 

 

The Autotest Report

 

 

 

 

 

 

 

 

Mukilteo Cable Co.

 

Test Summary: PASS

 

 

 

 

SITE: World Technology Ctr.

Cable ID: Rm16COAX34

 

 

 

OPERATOR: Mike Marshall

Date / Time: 01/07/97

10:50:12am

 

 

NVP: 80.0% FAULT ANOMALY THRESHOLD: 10%

Test Standard: Coax Cables

 

 

FLUKE DSP-2000 S/N: 6680915

Cable Type: 10Base2 (50 Ohms)

 

 

 

 

 

Software Version:

3.29

 

 

 

 

 

 

Standards Version: 3.06

 

 

 

Impedance (ohms), Limit 42-58

49

 

 

 

 

 

Length (ft), Limit 607

No Reflection

 

 

 

 

 

Prop. Delay (ns)

 

No Reflection

 

 

 

 

 

Resistance (ohms), Limit 48.0-65.0

50.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gc17f.eps

 

 

 

 

Figure 3-10. Autotest Report for Coaxial Cable

 

 

 

 

 

 

MUKILTEO CABLE CO.

 

 

 

 

 

Cable ID:

 

Date / Time:

SITE:

Length(ft):

 

 

 

RM1CBL1

01/06/97

09:51:46am

MOUNTAIN REAL ESTATE

 

77

PASS

 

 

RM1CBL2

01/06/97

09:56:53am

MOUNTAIN REAL ESTATE

 

98

FAIL

 

 

RM2CBL1

01/06/97

10:00:44am

MOUNTAIN REAL ESTATE

 

77

PASS

 

 

RM2CBL2

01/06/97

10:01:50am

MOUNTAIN REAL ESTATE

 

120

PASS

 

 

RM2CBL3

01/06/97

10:04:16am

MOUNTAIN REAL ESTATE

 

99

PASS

 

 

 

 

 

Total Length:

 

471

 

 

 

 

 

 

 

 

 

gc18f.eps

 

Figure 3-11. Autotest Report Summary

3-27