Running Individual Tests 4

When to Use a Remote Unit

1.If you are using a DSP-100 main unit as the remote, turn the remote unit’s rotary switch to SMART REMOTE. If you are using a smart remote unit, turn its rotary switch to ON.

2.Use a 2m patch cable of the correct impedance to connect the remote to the far end of the cable link.

3.On Model DSP-100, remove any cable connected to the test tool’s BNC connector.

4.Turn the rotary switch on the main unit to SINGLE TEST.

5.Use a 2m patch cable of the correct impedance to connect the test tool to the near end of the cable link. On Model DSP-2000, connect to the CABLE TEST jack.

6.Use UDto highlight the test you want to run.

7.Press Eto start the highlighted test.

Note

If a remote is required for the test, but is not connected, the test tool displays the message SCANNING FOR REMOTE and does not run the test until a remote is connected.

If the calibration message appears, refer to “Calibrating the Test

Tool” in Chapter 6 for complete calibration instructions.

4-5

Page 81
Image 81
Fluke DSP-100, DSP-2000 user manual Running Individual Tests