Manuals
/
Fluke
/
Computer Equipment
/
Network Card
Fluke
DSP-100
user manual
Automatic Diagnostics Model DSP-2000
Models:
DSP-2000
DSP-100
1
53
196
196
Download
196 pages
36.87 Kb
50
51
52
53
54
55
56
57
<
>
Troubleshooting
Specifications
Characteristic Impedance
Install
Attenuation of a Signal
Remote Communication Error
Setting the Power-Down Timer
Wire Map Test
Warranty
Dimension
Page 53
Image 53
Autotest
3
Automatic Diagnostics (Model
DSP-2000)
gc09c.eps
Figure
3-2.
Examples of Automatic Diagnostics Displays
3-5
Page 52
Page 54
Page 53
Image 53
Page 52
Page 54
Contents
DSP-100/2000
Limited Warranty & Limitation of Liability
Table of Contents
DSP-100/2000
Appendices
DSP-100/2000
List of Tables
Tests Run per Test Standard During an Autotest
List of Figures
Plot of NEXT, Attenuation, and the Resulting ACR
Introduction
Overview of Features
DSP-100/2000
Standard Accessories
Standard Accessories
Using This Manual
DSP-100/2000
International Electrical Symbols
Safety and Operational Information
DSP-100/2000
Using the Menus
Powering the Test Tool
Quick Start
Key
Quick Configuration Settings Description
Quick Configuration
Setup Setting
Press ! Choice
Asterisk and Test Tool Accuracy
Results within Accuracy Range
Autotest on Twisted Pair Cable
Horizontal Cross Connect Blocks Meters
Getting Started
Autotest on Coaxial Cable
Autotest on Coaxial Cable
DSP-100 DSP-2000
Main Unit Features
Main Unit Features Description
Feature
Standard and Smart Remote Features
Remote Features
Remote Connectors and Features
Remote Features
Off
Rotary Switch
Strap and Bail
Autotest
Monitor
Single Test
Setup
Print
Turning On the Test Tool
Special Functions
Smart Remote Model DSP-100
Performing a Self-Test
Selecting a Language for Displays and Reports
Overvoltage Test
Configuring the Test Tool
Noise Test
Controlling the Backlight
Selecting a Power Line Filter Frequency
Adjusting the Display Contrast
Selecting a Test Standard and Cable Type
Selecting an Average Cable Temperature
Selecting a Conduit Setting
Selecting a Numeric Format
Selecting a Length Unit
Setting the Date and Time
Enabling or Disabling the Audible Tones
Setting the Power-Down Timer
Remote Lights, Messages, and Audible Tones
Smart Remote Ready
Remote End Testing
Battery Status
Remote Communication Error
Battery Status Display
Autotest Softkeys
Autotest
Smart
Autotest
Link Performance Grade Result Headroom
Automatic Diagnostics Model DSP-2000
Automatic Diagnostics Model DSP-2000
Autotest Results for Twisted Pair Cable
Wire Map Test
Autotest Results for Twisted Pair Cable
Length
Resistance
Characteristic Impedance
Propagation Delay and Delay Skew
Items on the Attenuation Results Screen Description
Attenuation
Gc10c.eps
Items on the Next Results Screen Description
Next Test
Next Plot Screen Items on the Next Plot Screen Description
ACR
Items on the ACR Results Screen Description
ACR Plot Screen Items on the ACR Plot Screen Description
Items on the RL Results Screen Description
Return Loss RL
RL@REMOTE Model DSP-2000
Psnext Power Sum Next Model DSP-2000
Connector
Autotest Results for Coaxial Cable
No Reflection
Anomaly
Saving Autotest Results
Gc15c.eps
If Memory is Full
Autotest Report
Automatically Incrementing the Cable Identification Name
Part of an Autotest Report for Twisted Pair
10. Autotest Report for Coaxial Cable
DSP-100/2000
Single Tests for Twisted Pair Cable
Running Individual Tests
Scanning Function
When to Use a Remote Unit
Remote Requirements for Cable Tests Remote Unit
Test
Running a Single Test on Twisted Pair Cable
Running Individual Tests
Running the TDX Analyzer
TDX Analyzer
Items on the TDX Analyzer Results Screen
TDX Analyzer Results
TDX Analyzer Plot
TDR Test
How to Terminate the Cable
Running the TDR Test on Coaxial Cable
Running the TDR Test on Twisted Pair Cable
Items on a TDR Results Screen Twisted Pair Results
TDR Results Screen
TDR Plot Screen
Single Test Results for Twisted Pair Cable
Impedance
Wire Map
Next and NEXT@REMOTE
Running a Single Test on Coaxial Cable
Single Tests for Coaxial Cable
Return Loss RL and RL@REMOTE
Single Tests for Coaxial Cable
Single Test Results for Coaxial Cable
Monitoring Network Activity
Monitoring Network Activity
DSP-100/2000
Items on the Traffic Monitor Screen Description
Changing the Impulse Noise Threshold
Identifying Hub Port Connections
Monitoring Impulse Noise
Running the Impulse Noise Test
Use Dto highlight Impulse Noise on RJ45
Items on the Noise Monitor Screen Description
Determining Hub Port Capabilities Model DSP-2000
Noise Test Results
Using the Tone Generator Model DSP-2000
Printing Test Reports
Viewing and Printing Saved Reports
Printing
Configuring the Serial Port
Printer Interface Cable
Viewing and Printing Saved Reports Printing Test Reports
DSP-100/2000
If the Printer Does Not Respond
Viewing, Renaming, and Deleting Test Reports
Calibrating the Test Tool
Calibrations and Custom Test Standards
Connections for Self-Calibration DSP-2000 Shown
Use Dto highlight Determine Cable NVP
NVP Calibration
Configuring a Custom Cable
Page
DSP-100/2000
LAN Cable Construction
Basic Cable Testing
Twisted Pair Cable Construction
Twisted Pair Cable
568A
Coaxial Cable Construction
Coaxial Cable
Attenuation
Attenuation of a Signal
Sources of Electrical Noise
Noise
Characteristic Impedance
Minimizing Impedance Discontinuities
Crosstalk and Near-End Crosstalk Next
Locating Next Problems
A TDX Analyzer Plot
Basic Cable Testing
Split Pairs and Next
Incorrect Wiring Split Pair
Minimizing Crosstalk
NVP and Length Measurements
Nominal Velocity of Propagation NVP
NVP Calibration
Time Domain Reflectometry TDR
Short
Reflections from Opens
Reflections from Other Discontinuities
Reflections from Shorts
Interpreting the TDR Plot
Cable Termination
ACR
Frequency in MHz
Limit in dB
Finding Cable Faults
Troubleshooting Basics
Test Failure
Identifying Cable Faults Likely Causes of Failure
Identifying Cable Faults Examples of Test Displays and Plots
Identifying Cable Faults Test Failure
Next test fails Impedance anomaly is Detected
DSP-100/2000
Cleaning and Storage
Maintenance
Removing the Battery in the Standard Remote
Replacing the NiCad Battery Pack
Removing the NiCad Battery Pack
Internal Lithium Backup Battery
If the Test Tool Fails
Service Center Repair
Symptom 2 Remote unit is not detected
Troubleshooting the Test Tool Symptom 1 Display is blank
Symptom 3 Test results appear to be incorrect
Symptom 6 Self calibration fails
Part Number
Replacement Parts
Replacement Parts Description
Service Center Calibration Period
Specifications
Self-Calibration Period
Compatibility with Remote Units
Time for Autotest
Cable Types Tested
Test Standards
Length Test Specifications
Propagation Delay Test
Propagation Delay Test Specifications
Length Test
Next
DC Loop Resistance
Return Loss
TDX Analyzer Specifications for Cables 100m 328 ft
TDR Specifications for Cables 100m 328 ft
Model DSP-100 LAN Traffic
Impulse Noise
Model DSP-2000 LAN Traffic
Serial Interface
PC Interface Cable Connections Test Tool End DB9S female
25-pin Connector
PC Interface Cable
Environmental Requirements
Power
Input Ratings
Operating Environment Specifications
Weight
Dimensions
Certifications
Memory
Display
RJ45 Connector
Warranty
DSP-100/2000
Appendices
Page
Introduction
Using DSP-LINK
Preparing for Data Transfer
Installing DSP-LINK
Connecting to a PC
Figure A-1. Connecting the Test Tool to a PC
Configuring the Serial Ports
Communication Problems
Detailed Test Data Quick Plot
DSP-LINK Functions
DSP-100/2000
Table A-3. Formats for Uploaded Reports Courier Point Size
Formatting Hints for Uploaded Reports
Getting Software Updates from Fluke
Downloading New Test Standards
Downloading New Software
100BaseTX
10Base2
10BaseT
Broadband Signaling
Baseband Signaling
Auto-Negotiation
Bandwidth
Channel
Capacitance
Collision
Crossed Pair
CSV Data
Crosstalk
Download
EIA 568A
Horizontal Cabling
Hardware Flow Control
Horizontal Cross-Connect
Impedance Discontinuity
Link Pulse
Propagation Delay
Near-End Crosstalk Next
Packet
RJ45
Reversed Pair
Runt Packet
Screened Twisted Pair ScTP
TDXä
Split Pair
Terminator
Token Ring
XON/XOFF Flow Control
DSP-100/2000
Tests Run per Test Standard During an Autotest
Next
Tests Run per Test Standard During an Autotest C
Prop. Return Loss Delay2 Delay Skew2
TP-PMD
Return Loss
Prop Delay2 Delay Skew2
DSP-100/2000
Index
DSP-LINK
Next
DSP-100/2000
Index
DSP-100/2000
Manual Supplement
Change #1
Wire Map Displays Displayed Schematic Description
Wire Map Condition
Wire map display showing an open on pair 1
Wire map display showing a split pair on pairs 1, 2 and 3
Change #3
Top
Page
Image
Contents