Autotest 3

Autotest Results for Twisted Pair Cable

Wire Map Condition

Table 3-1. Wire Map Displays (continued)

 

 

 

 

Display

Schematic

Description

 

(only affected pairs

 

 

shown)

 

 

 

 

Crossed wires

Reversed pairs

Crossed pairs

Short

Open

1

2

3

6

gc44i.eps

1

2

gc46i.eps

1

2

3

6

gc48i.eps

1

2

3

6

gc50i.eps

1

2

gc52i.eps

1

2

3

6

gc45i.eps

1

2

gc47i.eps

1

2

3

6

gc49i.eps

1

2

3

6

gc51i.eps

1

2

gc53i.eps

A wire in the 1,2 pair is crossed with a wire in the 3,6 pair. Wiring does not form a recognizable circuit.

Wires 1 and 2 are crossed.

Pairs 1,2 and 3,6 are crossed.

Wires 1 and 3 are shorted. You can use the TDR test to locate the short.

Wire 1 is open. You can use the TDR test to locate the open.

Split pair

gc54i.eps

1

2

3

6

1

2

3

6

gc55i.eps

A wire in the 1,2 pair is twisted with a wire in the 3,6 pair. You can use the TDX analyzer to locate the split pair.

3-7

Page 55
Image 55
Fluke DSP-100, DSP-2000 user manual Autotest Results for Twisted Pair Cable