Fluke DSP-100, DSP-2000 user manual Items on the ACR Results Screen Description

Models: DSP-2000 DSP-100

1 196
Download 196 pages 36.87 Kb
Page 63
Image 63

Autotest 3

Autotest Results for Twisted Pair Cable

Item

Table 3-6. Items on the ACR Results Screen

Description

NEXT Pairs

Atten. Pair

Result

ACR (dB)

Frequency

Limit

Margin

The pairs that produced the crosstalk value used in calculating the ACR result.

The pair that produced the attenuation value used in calculating the ACR result.

The overall result for the ACR test. A PASS result means that the calculated ACR is higher than the value specified for the selected test standard. A FAIL result means that the calculated ACR is lower than the specified value.

The worst-case ACR. Worst-case ACR is the calculated ACR value that is closest to exceeding specifications. If the ACR exceeded specifications, the value displayed is the ACR value that exceeded specifications by the greatest amount.

The frequency where the worst-case ACR value is calculated.

The specified limit for the ACR at the worst-case frequency. The limit is defined by the test standard selected.

The difference between the worst-case ACR and the limit. A positive number means that the worst-case ACR is higher than the limit. A negative number means that the worst-case ACR is lower than the limit.