Appendix A Technical Specifications
Environmental and Technical Specifications for the Switch
Table | Technical | |
|
| |
Physical Dimensions |
| |
|
| |
Weight | 14.15 lb (6.42 kg) (no FRU installed) | |
|
| |
Dimensions (H x W x D) | 1.72 x 17.50 x 20.39 in. (4.37 x 44.45 x 51.79 cm) | |
|
| |
AC Power Requirements |
| |
|
| |
Input voltage | 100 to 240 VAC ± 10% (autoranging), 50 to 60 Hz. | |
|
| |
Power consumption with 1 AC power | Total: 656 BTUs per hour (maximum). | |
supply module and 1 fan module | Maximum: 192 W | |
installed | ||
Typical: 150 W (12 SFPs with | ||
| ||
| Minimum: 117 W (no cables or SFP modules installed). | |
| Power rating: 120 V (0.214 KVA), 230 V (0.209 KVA). | |
|
| |
Power consumption with 2 AC power | Total: 677 BTUs per hour (maximum). | |
supply modules installed | Maximum: 198 W | |
| ||
| Typical: 158 W (12 SFPs with | |
| Minimum: 126 W (no cables or SFP modules installed). | |
| Power rating: 120 V (0.220 KVA), 230 V (0.215 KVA). | |
|
| |
DC Power Requirements |
| |
|
| |
Input voltage | 18 to 32 VDC and 36 to 72 VDC. | |
|
| |
Power consumption with 1 DC power | Total: 711 BTUs per hour (maximum). | |
supply module and 1 fan module | Maximum: 208 W (18 VDC input, | |
installed | ||
Typical: 151 W (48 VDC, 12 SFPs with | ||
| ||
| traffic). | |
| Minimum: 117 W (48 VDC, no cables or SFP modules installed). | |
|
| |
Power consumption with 2 DC power | Total: 697 BTUs per hour (maximum). | |
supply modules installed | Maximum: 204 W, 18 VDC input (maximum fan speed, all ports linked). | |
| ||
| Typical: 157 W (48 VDC, SFP modules installed, 12 ports linked). | |
| Minimum: 124 W (48 VDC, no SFP modules installed). | |
|
|
Note If you install one AC and one DC power supply module in a switch, the power specifications are similar to two installed DC power supply modules.
Cisco ME 3800X and ME 3600X Switch Hardware Installation Guide
|
|
| |
|
|