Appendix A Technical Specifications
Environmental and Technical Specifications for the Switch
4.Acoustic noise is measured per ISO 7779 and declared per ISO 9296.
5.This can be limited by specification of optical modules.
Table | Technical | |
|
| |
Physical Dimensions |
| |
|
| |
Weight | 14.50 lb (6.58 kg) (no FRU installed) | |
|
| |
Dimensions (H x W x D) | 1.72 x 17.50 x 20.39 in. (4.37 x 44.45 x 51.79 cm) | |
|
| |
AC Power Requirements |
| |
|
| |
Input voltage | 100 to 240 VAC ± 10% (autoranging), 50 to 60 Hz. | |
|
| |
Power consumption with 1 AC power | Total: 779 BTUs per hour (maximum). | |
supply module and 1 fan module | Maximum: 228 W | |
installed | ||
Typical: 155 W (12 SFPs with | ||
| ||
| Minimum: 123 W (no cables or SFP modules installed). | |
| Power rating: 120 V (0.254 KVA), 230 V (0.248 KVA). | |
|
| |
Power consumption with 2 AC power | Total: 796 BTUs per hour (maximum). | |
supply modules installed | Maximum: 233 W | |
| ||
| Typical: 163 W (12 SFPs with | |
| Minimum: 132 W (no cables or SFP modules installed). | |
| Power rating: 120 V (0.259 KVA), 230 V (0.254 KVA). | |
|
| |
DC Power Requirements |
| |
|
| |
Input voltage | 18 to 32 VDC and 36 to 72 VDC. | |
|
| |
Power consumption with 1 DC power | Total: 840 BTUs per hour (maximum). | |
supply module and 1 fan module | Maximum: 246 W (18 VDC input, | |
installed | ||
Typical: 156 W (48 VDC, 12 SFPs with | ||
| ||
| traffic). | |
| Minimum: 124 W (48 VDC, no cables or SFP modules installed). | |
|
| |
Power consumption with 2 DC power | Total: 813 BTUs per hour (maximum). | |
supply modules installed | Maximum: 238 W (18 VDC input, | |
| ||
| Typical: 161 W (48 VDC, 12 SFPs with | |
| traffic). | |
| Minimum: 129 W (48 VDC, no cables or SFP modules installed). | |
|
|
Note If you install one AC and one DC power supply module in a switch, the power specifications are similar to two installed DC power supply modules.
Cisco ME 3800X and ME 3600X Switch Hardware Installation Guide
|
|
| |
|
|