Chapter 3 Installing and Removing AC and DC Input Power Supply and Fan Modules

Power Supply and Fan Module Installation

Figure 3-4 Power Supply and Fan Module Connector Side

1

1

1

207449

2

1

Fans

2

Connector pins

Power Supply and Fan Module Installation

Equipment That You Supply, page 3-4

Installation Guidelines, page 3-4

Installing an AC Power Supply Module, page 3-5

Installing a DC Power Supply Module, page 3-7

Installing a Fan Module, page 3-13

Equipment That You Supply

You need a ratcheting screwdriver with a Phillips head that exerts up to 15 inch-pounds (in-lb) of torque.

Installation Guidelines

Observe these guidelines when you install a fan or power supply module:

Do not force the fan or power supply module into the slot. This can damage the pins on the switch if they are not aligned with the unit.

A fan or power supply module that is only partially connected to the switch can disrupt the system operation.

Verify that you are using the correct power cord.

Warning Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed circuitry could constitute an energy hazard. Statement 206

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030

Cisco ME 3800X and ME 3600X Switch Hardware Installation Guide

3-4

OL-22168-01

 

 

Page 44
Image 44
Cisco Systems ME3600X24CXM Power Supply and Fan Module Installation, Equipment That You Supply, Installation Guidelines