A P P E N D I X A

Technical Specifications

Environmental and Technical Specifications for the Switch, page A-1

Environmental and Technical Specifications for the Power Supply and Fan Modules, page A-5

Environmental and Technical Specifications for the Switch

Table A-1

Environmental Ranges for the Switch

 

 

Environmental Ranges

 

 

 

Operating Environment and

Normal Operating Ambient Air Temperature and Altitudes

Altitude1, 2

 

23° to 122°F (–5º to 50ºC), up to 1,000 feet (300 m)

 

 

 

 

23° to 113°F (–5º to 45ºC), up to 6,000 feet (1800 m)

 

 

23° to 104°F (–5º to 40ºC), up to 10,000 feet (3000 m)

 

 

 

 

 

Short-Term3Exceptional Operating Ambient Air Temperature and

 

 

Altitudes

 

 

23° to 140°F (–5º to 60ºC), up to 1,000 feet (300 m)

 

 

23° to 131°F (–5º to 55ºC), up to 6,000 feet (1800 m)

 

 

23° to 122°F (–5º to 50ºC), up to 10,000 feet (3000 m)

 

 

23° to 113°F (–5º to 45ºC), at sea level with single fan failure

 

 

 

 

 

Normal Operating Internal Sensor Temperature

 

 

–4º to 158°F (–20º to 70ºC)

 

 

Acoustic Noise4

LpA: 43 dB typical, 46 dB maximum

 

 

LwA: 5.4 B typical, 5.6 B maximum

 

 

Relative humidity

5 to 95% (noncondensing)5.

Storage temperature

–40° to 158°F (–40° to 70°C).

 

 

 

Storage altitude

 

Up to 15,000 ft (4570 m).

 

 

 

1.GLC-T SFP can only be used from 23° to 122°F (–5º to 50ºC) up to 1,000 feet (300 m) environment for normal operating and short-term conditions.

2.The switch supports –5ºC operation provided that it powers up at ambient temperature equal to or greater than 0ºC. SFP-10G-LRM SFP+ module can only be used from 32° to 122°F (0º to 50ºC).

3.Not to exceed more than 96 consecutive hours, 360 total hours, or 15 occurrences in a 1-year period.

Cisco ME 3800X and ME 3600X Switch Hardware Installation Guide

 

OL-22168-01

A-1

 

Page 61
Image 61
Cisco Systems ME3600X24CXM manual Technical Specifications, Environmental Ranges