INSTALLATION INSTRUCTIONS - GENERAL SAFETY INFORMATION

1.This installation must conform with local codes or, in the ab- sence of local codes with NFPA54.

2.Provide adequate clearances around the product for servic- ing and ensure there are no obstructions to the combustion air intake situated at the back of the heater. Refer to Page 15, Figures 7 through 10.

3.The appliance must be installed on a flat, solid continuous surface (i.e. wood, metal, concrete). Please Note: Rough or uneven surfaces can cause vibration or humming in the heat- er.

4.The Mantis Power-Vent High-Effeciency Fireplace can be in- stalled in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner. For installation options re- fer to page 15.

5.This appliance (Insert and Freestanding Models) needs to be installed in such a way that the heater can be removed at all times to service the heater exchanger and flue fan located in the rear section of the heater.

Note: Under no circumstances should the appliance be in- stalled under conditions which would not allow for easy removal of the appliance to carry out routine inspection and service to the appliance, to do so will void the warranty.

Note: On Single Wall flue pipe installations (imitation zero clearance fireplace) a minimum of 2” (50.8 cm) clear- ance must be provided at the rear of the heater to enable the heater to get sufficient combustion air to the air inlet located at the rear of heater. Refer to installation instruc- tions on page 15, Figures 7 through 10.

Note: Where a mantel surround is being used on insert installa- tions and zero clearance fireplace installations, the com- bustion air intake slot located in the top mantel surround must have no obstructions to allow combustion air to en- ter through the slot to the combustion air inlet located at the back of the heater.

SPECIFICATIONS

Model

PV28SV50

Input BTU/HR (KW/H)

19,000 Rear - 9,000 Front

Height

25

1/8”

Width

28

3/16”

Depth

17

5/8”

Gas Inlet (Pipe)

3/8” Flair

Electrical - Unit has a 5’ (1.5 m) 3 pronged cordset for con- nection to an approved 115 VAC 60 Hz maximum AMPs - 5A wall receptacle.

Accessories

Part Number

Description

PV-2H

Top Cover - Slim Assembly

PV-4H

Top Cover - Short Assembly

PVPK

Pedestal Kit

PVE-1

6” Surround Assembly

PVSH

Rear Shroud

TRW

Wall Thermostat - Wireless Remote

FRBTC

Battery Operated Remote w/Thermostat

FRBTP

Battery Operated Remote w/Programmable Ther-

 

mostat

T24V

24 Volt Thermostat

TMV2

Two-Stage Thermostats

CIPFP-1

Floor Pad Kit

CIFPB-1C

Corner Floor Pad Kit

PVVK24H

Direct Vent 24” Vent Kit

PVVK48H

Direct Vent 48” Vent Kit

PVVK-SH

Single Flue Horizontal Vent Kit

PVVK-SV

Single Flue Vertical Vent Kit

PVVK-CFA

Flex Vent Kit

PVCT

Colinear Transition

PVVTC

Vertical Termination Cap - 1.5”

PVCA

Colinear Adapter

Page 8

24820-1-0409

Page 8
Image 8
Empire Comfort Systems PV-28SV50-B2H(N,P)-1 Specifications, Installation Instructions General Safety Information