Empire Comfort Systems PV-28SV50-B2H(N,P)-1, PV-28SV50-B(N,P)-1 Rough Framing Dimensions

Models: PV-28SV55-(C,G)2H(N,P)-1 PV-28SV50-B2H(N,P)-1 PV-28SV55-(C,G)(N,P)-1 PV-28SV50-B(N,P)-1

1 56
Download 56 pages 11.92 Kb
Page 16
Image 16
ROUGH FRAMING DIMENSIONS

ROUGH FRAMING DIMENSIONS

A - 13

/34” MIN. CO-LINEAR

8

1/2” WHEN USING DIRECT VENTING

PVVK-24H/PVVK-48H

NOTE: DIMENSIONS FOR USE WITH SHORT TOP

PV4H. THIS IS RECOMMENDED FOR UNIT

SERVICEABILITY.

B - 25 1/8”

C - 28”

NOTE: IF TRIM AROUND HEATER IS NECESSARY,

THE SURROUND KIT PVE-1 MUST BE USED,

AND SUBTRACT 1” FROM (A) DIMENSION.

Figure 12

INSERT INTO MASONRY FIREPLACE

A

-

12

3/4” MIN. SHORT TOP PV4H

 

 

17

13/16” MIN. SLIM TOP PV2H

 

 

USING PVE-1 SURROUND KIT

B

-

25

1/8” MIN. DIRECT VENT

 

 

26

1/2” MIN. SINGLE FLUE

 

 

29” MAX

C

-

28” MIN. NO SURROUND

 

 

33” MIN. WITH PVE-1 SURROUND

 

 

35” MAX. WITH PVE-1 SURROUND

Figure 13

Page 16

24820-1-0409

Page 16
Image 16
Empire Comfort Systems PV-28SV50-B2H(N,P)-1, PV-28SV50-B(N,P)-1 Rough Framing Dimensions, Insert Into Masonry Fireplace