Empire Comfort Systems PV-28SV55-(C,G)(N,P)-1 Clearance To Combustibles, Freestanding Units

Models: PV-28SV55-(C,G)2H(N,P)-1 PV-28SV50-B2H(N,P)-1 PV-28SV55-(C,G)(N,P)-1 PV-28SV50-B(N,P)-1

1 56
Download 56 pages 11.92 Kb
Page 15
Image 15
CLEARANCE TO COMBUSTIBLES

CLEARANCE TO COMBUSTIBLES

Freestanding Models

A

BBFreestanding Units CCSingle Flue

 

Figure 7

Figure 8

 

 

 

 

 

Freestanding Units

A

Rear Wall to Heater

0” (2” Single Flue and 1 1/4” Direct Vent for Serviceability)

B

Side Wall to Heater

0” (4” recommended for serviceability)

C

Corner Installation

0”

D

Mantel Clearance

See Figure 11

Fireplace Insert

Single Flue

Requires surround for combustion air.

Do not cover surround louver.

Figure 9

CEILING

8”

6”

40”

4”

24”

18”

12”

COMBUSTIBLE TRIM AND MANTELS

ALLOWED IN SHADED AREA

Mantel and Ceiling Clearances

Direct Vent Installation Shown

Figure 11

Single Flue requires surround for combustion air.

Figure 10

Note: The Mantis Power-Vent High-Efficiency Fireplace has been tested and approved for zero clearance to combustible materials. Empire Comfort Systems, Inc. recommends that clearances as listed above should be maintained to allow for removal of the product for servicing.

24820-1-0409

Page 15

Page 15
Image 15
Empire Comfort Systems PV-28SV55-(C,G)(N,P)-1 Clearance To Combustibles, Freestanding Units, Mantel and Ceiling Clearances