Empire Comfort Systems PV-28SV55-(C,G)2H(N,P)-1 Optional Controllers, Temperature Controllers

Models: PV-28SV55-(C,G)2H(N,P)-1 PV-28SV50-B2H(N,P)-1 PV-28SV55-(C,G)(N,P)-1 PV-28SV50-B(N,P)-1

1 56
Download 56 pages 11.92 Kb
Page 42
Image 42
OPTIONAL CONTROLLERS

 

 

OPTIONAL CONTROLLERS

 

 

 

 

 

 

 

 

 

 

TEMPERATURE CONTROLLERS

 

 

 

 

 

 

FRBTP

Battery Operated Remote w/ Programmable Thermostat

 

 

FRBTC

Battery Operated Remote w/ Thermostat

 

 

TRW

Battery Operated Wireless Remote Wall Thermostat

 

 

TMV2

Thermostat, 2 Stage

 

 

T24V

Thermostat, 24 Volt

 

See your Mantis dealer for correct controller type.

INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION Installation Instructions for FRBTP, FRBTC, and TRW

Remote Controls FRBTP, FRBTC and TRW are all battery operated devices. Begin installation by unplugging the unit and removing the front louver panel.

Remove wire nut from black and white wire from junction box.

Black or white wire can be inserted in either remote control receiver connection hole or connected to T24V thermostat screws. There is no polarity at this connection.

REMOTE

CONTROL

RECEIVER OR

T24V THERMOSTAT

BLACK

WHITE

WHITE TEMPERATURE CONTROLLERS

JUNCTION

C W2 W1 R

 

 

 

 

 

BLOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

TO “T1” (FRONT BURNER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

TO “T2” (REAR BURNER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

 

TO “T1”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

TO “T2”

 

 

 

 

 

 

 

 

 

 

Figure 49

Replace front louver panel and plug unit into outlet. Turn both burner switches to the ON position. Burner switches must remain in the ON position for remote to function. Set remote from the instructions provided with the remote control. Set T24V thermostat to desired temperature.

Note: When the heater will not be used for long periods, the burner switches should be in the OFF position, and the heater should be turned off at the power point.

Installation Instruction for TMV2 - Two Stage Thermostat Model:

Begin installation by unplugging the unit and removing the front louver panel.

Determine mounting location of thermostat. Using standard 18 AWG wire, run four (4) strands of wire into rear of Mantis (See Figure 50) to junction block. Cut wire to correct length. Remove blue jumper wire from junction block and save for future use. Connect four (4) new thermostat wires to Mantis using schematic. See Figure 51.

Page 42

Figure 50

24820-1-0409

Page 42
Image 42
Empire Comfort Systems PV-28SV55-(C,G)2H(N,P)-1, PV-28SV50-B2H(N,P)-1 Optional Controllers, Temperature Controllers