MAIN CONVECTION FAN
The main convection fan in the heater should be checked, ser- | Note: If the main convection fan becomes clogged with lint and |
viced and cleaned annually by a qualified service person to ensure | dust an |
that your appliance is operating efficiently. | heater exchange system and the |
| switch will stop the heater from operating. |
HEAT EXCHANGER
The heat exchanger of the unit is located at the rear of the heater. The heat exchanger should be inspected annually by a qualified service person for lint and dust build up. Excessive dust and lint
Note: This appliance (Insert and Freestanding Models) needs to be installed in such a way that the heater (especially with models built into a fireplace) can be removed at all times to service the heat exchanger and flue fan, which
are located at the rear section of the heater.
Under no circumstances should the appliance be installed under conditions that would not allow for easy removal of the appliance to carry out routine inspection and ser- vice work on the appliance.
DISCONNECT MAIN POWER PRIOR TO STARTING ANY WORK ON THE APPLIANCE.
SURROUND INSTALLATION INSTRUCTIONS
1.Remove Fireplace Insert Surround assembly from carton, handle insert surround with care to avoid paint damage.
2.Assembly Fireplace Insert Surround as per diagram with four (4) 10 x 1/2” screws supplied.
3.Install surround assembly around fireplace.
4.Install either slim or short top. Note: Top will hold surround in place.
COMBUSTION AIR | SURROUND TOP | COMBUSTION AIR |
INTAKE SLOT |
| DEFLECTOR |
|
| SURROUND SIDE |
| 4 SCREWS |
|
Figure 57 |
| Figure 58 | ||
|
| PARTS LIST |
|
|
| Part Number | Description | Quantity Supplied |
|
| 22754 | Top, Surround Assembly | 1 |
|
21859 | Side, Surround 6” | 2 |
|
Replacement 10 x 1/2” screws can be purchased from a local hardware store.
Page 48 |