Chapter 3 Installing and Removing AC and DC Input Power Supply and Fan Modules

Power Supply and Fan Module Installation

Figure 3-9 Crimping the Ground Lug

280938

Step 5 Attach the dual-hole lug and the wire assembly to the chassis ground connection with the supplied screws (Figure 3-10).

Figure 3-10 Attaching the Ground Lug and Wire Assembly

207475

1

1

Dual-hole ground lug

Step 6 Use a ratcheting torque Phillips-head screwdriver to torque the ground-lug screws to 32 in-lb.

Step 7 Connect the other end of the grounding wire to an appropriate grounding point at your site or to the rack.

Cisco ME 3800X and ME 3600X Switch Hardware Installation Guide

 

OL-22168-01

3-9

 

 

 

Page 49
Image 49
Cisco Systems ME3600X24CXM manual Crimping the Ground Lug