MACHINE TROUBLESHOOTING

MACHINE TROUBLESHOOTING

PROBLEM

CAUSE

Poor or no water pick-up

Squeegee out of adjustment

on either squeegee

 

Debris caught on squeegee

 

Worn squeegee blades

 

Vacuum hose clogged

 

Vacuum hose disconnected

 

from squeegee or recovery

 

tank

 

Vacuum hose damaged

 

Recovery tank not sealed

 

Foam filling recovery tank

Vacuum motor does not run, or

Recovery tank full

runs slowly

 

Recovery tank float system

 

dirty

 

Circuit breaker tripped

 

Loose connection

 

Faulty vacuum switch

 

Worn vacuum motor

 

brushes

Poor scrubbing performance

Debris caught in scrub

brushes

 

Worn brushes or pads

 

Improper detergent, brush or

 

pad used

 

Low scrub brush down

 

pressure

 

Low battery charge

Brush motors do not run, or runs

Circuit breaker(s) tripped

slowly

 

Loose connection

 

Faulty brush motor contactor

 

Worn brush motor brushes

SOLUTION

Adjust squeegee Remove debris

Rotate or replace squeegee blades

Clear obstruction from hose

Reconnect vacuum hose Replace vacuum hose Place recovery tank dome on tank. Replace damaged gaskets. Empty recovery tank

Use less or different detergent Use defoamer

Drain recovery tank

Clean float system Reset circuit breaker Check motor wires and connections Replace switch Replace brushes, check commutator

Remove debris

Replace brushes or pads Contact equipment or application specialist

Increase brush pressure

Charge batteries

Reset circuit breaker(s) Check motor wires and connection

Replace contactor Replace brushes, check commutator