DSP-100/2000

Users Manual

1.Turn the rotary switch to MONITOR.

2.Use Dto highlight either 10BaseT Traffic on RJ45

(10/100BaseTX Traffic on RJ45 on Model DSP-2000) or 10Base2 Traffic on BNC.

3.Remove any cable connected to the test tool’s unused test connector.

4.Use a patch cable of the correct impedance to connect the test tool to the network as shown in Figure 4-5. On Model DSP-2000, connect to the jack indicated by the arrow at the top of the display. Use the RJ45 to BNC adapter if necessary.

5.Press T to start the traffic test.

6.When using Model DSP-2000, use the #10T Only or

#100TX Only softkey to select traffic monitoring at 10 Mb/s or 100 Mb/s.

If you don't know which speed to use, and the test tool is not already trying to link using Auto-Negotiation, press #until the display reads Auto-Negotiation. This causes the test tool to select the proper speed to match the hub.

As the traffic test runs, the results shown on the test tool’s display are updated every second. Table 4-7 describes the items on the screen.

4-18

Page 94
Image 94
Fluke DSP-2000 user manual DSP-100/2000