Fluke DSP-2000, DSP-100 user manual Part of an Autotest Report for Twisted Pair

Models: DSP-2000 DSP-100

1 196
Download 196 pages 36.87 Kb
Page 74
Image 74

DSP-100/2000

Users Manual

The result printed on a report summary can be a pass or fail, or warning. A failure of any test required by the selected test standard produces a fail result on the report summary. A warning appears on reports for twisted pair cable if a length, impedance, propagation delay, or delay skew test produced a warning. The table in Appendix C shows which test standards can produce a warning result for these tests.

Mukilteo Cable Co.

 

 

 

Test Summary: FAIL

 

 

SITE: Westshore Business Park

 

 

Cable ID: Bldg7Rm9Cbl3

 

OPERATOR: Kim Nguyen

 

 

 

Date / Time: 01/07/97

 

10:01:05am

NVP: 69.0% FAULT ANOMALY THRESHOLD: 15%

 

Test Standard: TIA Cat 5 Channel

FLUKE DSP-2000 S/N: 6680915

 

 

Cable Type: UTP 100 Ohm Cat 5

HEADROOM: -20.4

 

 

 

Software Version: 3.29

 

 

 

 

 

Standards Version: 3.06

 

Wire Map FAIL

 

Result

RJ45 PIN:

1 2 3 4 5 6 7 8

S

 

Split pairs detected:

1,2-3,6

 

 

 

 

Patch Cable BAD or Patch Cable too short

RJ45 PIN:

1 2 3 4 5 6 7 8

 

 

Pair

 

 

1,2

3,6

 

4,5

 

7,8

Impedance (ohms), Limit 80-120

 

107

105

W

106

 

108

Anomaly (ft)

 

 

 

71

 

 

 

 

Length (ft), Limit 328

 

 

75

77

 

74

 

74

Prop. Delay (ns)

 

 

110

113

 

109

 

109

Delay Skew (ns), Limit 50

 

1

4

 

0

 

0

Resistance (ohms)

 

 

4.6

4.9

 

4.9

 

4.6

Attenuation (dB)

 

 

5.1

6.7

 

5.2

 

4.9

Limit (dB)

 

 

24.0

22.5

 

24.0

 

24.0

Margin (dB)

 

 

18.9

15.8

 

18.8

 

19.1

Frequency (MHz)

 

 

100.0

88.3

 

100.0

 

100.0

Pairs

1,2-3,6

1,2-4,5

1,2-7,8

3,6-4,5

 

3,6-7,8

 

4,5-7,8

NEXT (dB)

36.6 F

43.5*F

40.2

26.1

F

31.8

F

50.1*F

Limit (dB)

49.2

44.6

34.9

46.5

 

45.6

 

50.8

Margin (dB)

-12.6

-1.1

5.3

-20.4

 

-13.8

 

-.7

Frequency (MHz)

4.9

9.3

35.4

7.1

 

8.1

 

3.9

* Measurement is within the accuracy limits of the instrument.

gc16f.eps

Figure 3-9. Part of an Autotest Report for Twisted Pair

3-26

Page 74
Image 74
Fluke DSP-2000, DSP-100 user manual Part of an Autotest Report for Twisted Pair