Configuring a Custom Cable

The Configure Custom Cable function allows you to define custom test standards for up to four custom cables. You can change the following parameters for your custom configuration:

Baseline standard for cable definition

NVP (Nominal Velocity of Propagation)

Maximum cable length

Fault threshold for impedance anomalies

Active pair assignments for cable pairs

Resistance

Characteristic impedance test enabled or disabled

Attenuation test enabled or disabled

NEXT and NEXT@REMOTE tests enabled or disabled

RL test enabled or disabled

ACR and ACR@REMOTE tests enabled or disabled

PSNEXT and PSNEXT@REMOTE tests enabled or disabled (Model DSP-2000)

Note

To determine the NVP for a custom cable configuration refer to the previous section, “NVP Calibration.”

During the configuration process, you can abandon the changes you have made by pressing ! Abort. To reset a parameter back to the default value, highlight the parameter; then press @ Set to Default. To reset all of the parameters back to default values, highlight the test standard on Page 1 of 6 of the configuration screens; then press @ Set to Default.