Fluke DSP-2000, DSP-100 user manual Identifying Cable Faults Test Failure

Models: DSP-2000 DSP-100

1 196
Download 196 pages 36.87 Kb
Page 136
Image 136

DSP-100/2000

Users Manual

Table 7-1. Identifying Cable Faults (continued)

Test Failure

Wire map: short

Likely Causes of Failure

Wires connected to wrong pins at connector or punchdown blocks. Conductive material stuck between pins at a connection.

Damage to cable insulation.

NEXT

Impedance anomaly detected

Excessive untwisting of pairs at connection.

Insufficient quality of connecting hardware.

Damage to cable (pinches, kinks, etc.)

Damaged connector

Insufficient cable quality.

Poor connection between two lengths of cable.

Damage to cable (pinches, kinks, etc.)

Taps into wire pair. (Twisted pair cable should never be tapped.) Excessive loading at coaxial cable tap.

Mismatch of cable types.

Incorrect terminator value.