IMPORTANT SAFETY INFORMATION

DFX & DBX Series Vent Free Fireplaces

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

WARNING

Any change to this heater or its controls can be dangerous.

Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.

Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

Do not use a blower insert, heat exchanger insert or other accessory, not approved for use with this heater where applicable.

1.Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

2.Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.

3.Young children should be carefully supervised when they are in the same room with the appliance.

4.Do not place clothing or other flammable material on or near the appliance.

5.Any safety screen or guard removed for servicing an appliance, must be replaced prior to operating the heater.

6.Installation and repair should be done by a qualified service person.

7.To prevent malfunction and/or sooting, an unvented gas heater should be cleaned before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways be kept clean.

8.CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the heater serviced as it may not be operating properly.

9.The installation must conform with local codes or, in the absence of local codes, with the National Fuel

Gas Code, ANSI Z223.l/NFPA54.

10.Do not install the DFX model in a bathroom or bedroom. The DBX model may be installed in a bedroom, but not in a bathroom.

11.Correct installation of the ceramic fiber logs, proper location of the heater, and annual cleaning are neces- sary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace. Refer to log placement instructions for proper installation.

33D4047

12.Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.

13.Caution: Candles, incense, oil lamps, etc. produce combustion byproducts including soot. Vent-free appli- ances will not filter or clean soot produced by these types of products. In addition, the smoke and/or aro- matics (scents) may be reburnt in the vent-free appli- ance which can produce odors. It is recommended to minimize the use of candles, incense, etc. while the vent-free appliance is in operation.

14.This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provi- sions for adequate combustion and ventilation air must be provided. Refer to Page 8.

15.Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

16.Unvented gas heaters are a supplemental zone heater. They are not intended to be the primary heating appli- ance.

17.Unvented gas heaters emit moisture into the living area. In most homes of average construction, this does not pose a problem. In houses of extremely tight construction, additional mechanical ventilation is recommended.

18.During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.

The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.

Page 3
Image 3
Monessen Hearth DBX24C manual Important Safety Information, Installer, Owner

DBX24C specifications

The Monessen Hearth DBX24C is a remarkable addition to the landscape of home heating solutions. Known for its efficient performance and modern design, this direct vent gas fireplace offers both functionality and aesthetic appeal, making it a top choice among homeowners.

One of the standout features of the DBX24C is its sleek, contemporary appearance. The fireplace has a clean face design that maximizes the viewing area of the flames, creating a captivating focal point in any room. It is available in various decorative options, including multiple media layouts, which allow users to personalize their fireplace to match their interior decor.

Efficiency is a key characteristic of the Monessen Hearth DBX24C. With an impressive efficiency rating, it provides effective heating while utilizing fuel resources wisely. The direct vent design ensures that combustion gases are expelled outside, promoting safer indoor air quality and allowing for versatile installation options, including exterior walls and through the roof.

Equipped with advanced technologies, the DBX24C boasts an impressive burner system that produces an alluring flame pattern, replicating the look of real wood. This fireplace uses high-quality ceramic glass that not only provides durability but also enhances heat output. The ceramic glass allows for excellent visibility of the flames while reflecting heat back into the living space.

The DBX24C features user-friendly controls, with options for remote operation and adjustable flame settings. This enables homeowners to easily customize their heating experience, whether they desire a cozy ambiance for gatherings or a warmer atmosphere on chilly nights. Additionally, its minimal maintenance requirements make it a practical choice for busy homeowners.

In terms of safety, the Monessen Hearth DBX24C incorporates several built-in features, such as heat sensors that monitor the unit’s temperature and safety shutoff systems that activate if the fireplace reaches excessive heat levels. This commitment to safety further enhances its appeal for families.

In summary, the Monessen Hearth DBX24C offers an exceptional blend of efficiency, style, and technology. Its modern design, customizable features, and commitment to safety make it an outstanding choice for those seeking a reliable and aesthetically pleasing heating solution for their homes. Whether you are looking to enhance your living space with a beautiful centerpiece or simply desire effective warmth, this gas fireplace delivers on all fronts.