Monessen Hearth DBX24C manual DFX & DBX Series Vent Free Fireplaces, Fireplace Installation, leaks

Models: DBX24C

1 36
Download 36 pages 33.98 Kb
Page 14
Image 14
Do not use open flame to check for gas

DFX & DBX Series Vent Free Fireplaces

FIREPLACE INSTALLATION

When tightening the joint to the valve, hold the valve securely to prevent movement.

Test all gas joints from the gas meter to the heater valve for leaks using a gas analyzer or soap and water solution after completing connection. DO NOT USE AN OPEN FLAME.

Check the gas pressure with the appliance burning and the control set to HIGH.

Open control access door at bottom front of unit to find valve and regulator referred to below.

WARNING

Do not use open flame to check for gas

 

 

leaks.

 

 

Manual Control

Figure 12

The pressure regulator is preset and locked to discourage tampering. If the pressure is not as specified, replace the regulator with the correct part from the parts list in this manual.

Remove 1/8" NPT plug, located on side of regulator body. Install fitting and tubing to pressure gauge. After taking pressure reading, reinstall test plug. Check for gas leaks.

WARNING

Connecting directly to an unregulated

 

 

propane/LP tank can cause an

 

explosion.

 

 

Test Points

FP2510

Figure 13 -

Alternate Test Point Location for

Thermostat control Units

NPT Test Plug

Figure 12 -

FP2499

Pressure Test Point Location

 

- Manual Control

 

Thermostat Control

Figure 13

Turn captured screw counter clockwise two or three turns and then place tubing to pressure gauge over test point (Use test point closest to control knob). After taking pres- sure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check for gas leaks.

Millivolt Control

Figure 14

The valve regulator controls the burner pressure which should be checked at the pressure test point.

FP2511

Test Port 'A'

Figure 14 -

Pressure Test Point Location - Millivolt Valve

Turn captured screw counter clockwise two or three turns and then place tubing to pressure gauge over test point. (Use test point “A” closest to gas inlet). After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check for gas leaks.

14

33D4047

Page 14
Image 14
Monessen Hearth DBX24C DFX & DBX Series Vent Free Fireplaces, Fireplace Installation, leaks, propane/LP tank can cause an