FLAME APPEARANCE | DFX & DBX Series Vent Free Fireplaces |
Checking burner flame
DFX24C and DFX32C models
In normal operation at full rate after 15 minutes, the follow- ing flame appearances should be observed:
Burner will have a random pattern of yellow flames. Fig- ures 25 and 26. There should be glowing embers in front of burner.
DBX24C model
In normal operation at full rate after 15 minutes, the follow- ing flame appearances should be observed:
The flames inside the
NOTE: The front flames and embers will be an opaque orange color during the burn off time.
Figure 25 -
DFX24C Log Flame Appearance
LG703
Figure 26 -
DFX32C Log Flame Appearance
LG704 | Figure 27 - |
| |
| DBX24C Log Flame Appearance |
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the fireplace. Do not place a blower inside the burn area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.
The initial
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace.
2” - 4”
LG705
33D4047 | 21 |