PRODUCT FEATURES | DFX & DBX Series Vent Free Fireplaces |
Fireplace
Screen
| Control |
| Knob |
| Piezo |
| Ignition |
Figure 1 - | On/Off Switch |
FP2507 |
Unvented Gas Heater
(Control Access Door Shown Open)
This
operation
This unvented gas heater requires no outside venting and burns cleanly with high heating efficiency.
This
GAS pressures
|
| Manual & |
|
Control | Fuel | Millivolt | |
Regulator Pressure | Nat. | 4.0” w.c. | 3.5” w.c. |
Pilot Regulator | Nat. | n/a | 3.5” w.c. |
Max. Inlet Pressure | Nat. | 10.5” w.c. | 10.5” w.c. |
Min. Inlet Pressure | Nat. | 5.0” w.c. | 5” w.c. |
Regulator Pressure | LP | 10.0” w.c. | 10.0” w.c. |
Max. Inlet Pressure | LP | 13.0” w.c. | 13.0” w.c. |
Min. Inlet Pressure | LP | 11.0” w.c. | 11.0” w.c. |
|
|
|
|
33D4047
Gas Specifications
|
|
| Input BTU/hr | |
Model | Fuel | Control | Max. | Min. |
24DFXNMC | Nat. | Manual | 22,000 | 15,000 |
24DFXPMC | LP | Manual | 22,000 | 17,000 |
24DFXNVC | Nat. | Millivolt | 22,000 | 17,000 |
24DFXPVC | LP | Millivolt | 22,000 | 17,000 |
32DFXNVC | Nat. | Millivolt | 26,000 | 20,000 |
32DFXPVC | LP | Millivolt | 26,000 | 20,000 |
DBX24NTC | Nat. | 10,000 | ||
DBX24PTC | LP | 10,000 |
NOTE: For LP models an external regulator is required to reduce supply pressure to a maximum of 13" w.c.
ignition controls
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI - Variable position to control flame height (heat output). Both front and rear burners are in operation to provide realistic glow and yellow flame.
Thermostat control has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
LOW/HI - Variable position corresponding to desired temperature.
Pilot
The gas log heater is fitted with a specially designed safety pilot light which senses the amount of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can only be relit when adequate fresh air is available.
Thermal Generator
The millivolt gas log pilot is fitted with a millivolt generator to provide power for remote activation.