Cisco Systems ME 3400 manual Inserting and Removing the SFP Module Patch Cable

Page 43

Chapter 2 Switch Installation

Inserting and Removing the SFP Module Patch Cable

Step 5 For fiber-optic SFP modules, insert a dust plug into the optical ports of the SFP module to keep the optical interfaces clean.

Step 6 Place the removed SFP module in an antistatic bag or other protective environment.

Inserting and Removing the SFP Module Patch Cable

To insert an SFP module patch cable into the SFP module slot, follow these steps:

Step 1 Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface on the chassis.

Step 2 Insert the SFP module patch cable into the slot until you feel the connector on the cable snap into place in the rear of the slot (see Figure 2-15).

Figure 2-15 Inserting an SFP Module Patch Cable into an SFP Module Slot

Cisco ME

1

2

3400

SERIES

132676

Step 3 Repeat these steps for the second Cisco ME switch to which you want to cascade the first switch. See Figure 2-16.

Figure 2-16 Connecting Two Cisco ME Switches with an SFP Module Patch Cable

SYSTEM

RATING

 

 

 

100-240V

~

 

 

1A-0.5A,

 

HZ

 

 

50-60

CONSOLE

 

 

 

 

 

 

 

 

SYSTEM

RATING

 

 

 

100-240V

 

 

 

1A-0.5A,

 

~

HZ

 

 

50-60

CONSOLE

 

 

 

 

1

2

4

 

 

 

 

 

1X

3

6

 

 

 

 

 

5

8

 

 

 

 

 

 

7

10

 

 

 

 

 

 

9

11

12

 

 

 

 

 

 

 

11X

2X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12X

1

2

4

 

 

 

 

 

1X

3

6

 

 

 

 

 

5

8

 

 

 

 

 

 

7

10

 

 

 

 

 

 

9

11

12

 

 

 

 

 

 

 

11X

2X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12X

13

14

13X

 

14X

 

13

14

13X

 

14X

 

15

16

17

18

 

 

 

 

 

 

 

 

 

 

19

20

21

22

 

 

 

 

 

 

 

 

23

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23X

15

16

17

18

 

 

 

 

 

 

 

 

 

 

19

20

21

22

 

 

 

 

 

 

 

 

23

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23X

 

 

 

 

 

 

 

 

 

24X

Cisco ME

1

2

Cisco ME

1

2

3400

3400

SERIES

SERIES

132677

To remove an SFP module patch cable from the SFP module slot, release the connector, and pull it from the SFP module slot.

Cisco ME 3400 Ethernet Access Switch Hardware Installation Guide

 

OL-7677-04

2-19

 

 

 

Image 43
Contents Americas Headquarters Page N T E N T S Installing and Removing SFP Modules Speed, Duplex, and Autonegotiation IP Settings D-2 Purpose AudienceOrganization Conventions Related Publications OL-7677-04 Switch Models Setting up the SwitchFront Panel Description 1describes the switch modelsCisco ME 3400-24TS AC Ethernet Access Switch Front Panel Cisco ME 3400-24TS AC and DC Switches Front PanelCisco ME 3400G-12CS AC and DC Switches Front Panel Cisco ME 3400-24FS Switch AC Switch Front PanelSystem LED Dual-purpose ports Console port SFP module ports Cisco ME 3400G-2CS Switch Front Panel10/100 Ports Only the Cisco ME-3400-24TS Switches SFP Modules SFP Module PortsThese illustrations show the location of the System LED LEDsSFP Module Patch Cable System LEDConsole Port LEDs Power Supply LEDs Only Cisco ME 3400G-12CS SwitchesDual-Purpose Port LEDs Console PortExhaust fan Cable lock Ground connector Cisco ME 3400-24TS Switch Rear PanelCisco ME 3400-24FS Switch Rear Panel Cable lock Ground connector Fan exhaustFan exhaust AC power connector Ground connector Power Supply FeaturesCisco ME 3400G-12S Switch Rear Panel Cisco ME 3400-2CS Switch Rear PanelManagement Options Cisco ME AC Switch Power SupplyCisco ME DC Switch Power Supply Network ConfigurationsThis section covers these topics Preparing for InstallationSwitch Installation Preparing for Installation 122F 50C Statement Cisco ME 3400-24TS Switches Installation GuidelinesCisco ME 3400G-12CS Switches This section describes these installation procedures Verifying Switch OperationInstalling the Switch Powering Off the SwitchRack-Mounting Removing Screws from the SwitchRack-Mounting Brackets Attaching Brackets to the SwitchAttaching Brackets to 19-Inch Racks 191022 Attaching Brackets for 23-Inch Racks Attaching Brackets for 24-Inch Racks Attaching Brackets for Etsi Racks Phillips machine screws Cable guide and screw Mounting the Switch in a RackWall-Mounting Attaching the Brackets to the Switch for Wall-MountingPhillips flat-head screws 11 Mounting the Switch on a Wall Mounting the Switch on a WallTable- or Shelf-Mounting Installing and Removing SFP Modules12 SFP Module with a Bale-Clasp Latch Installing SFP ModulesBale clasp Removing SFP ModulesInserting and Removing the SFP Module Patch Cable 17 Connecting to an Ethernet Port Connecting to the 10/100 and 10/100/1000 PortsConnecting to Fiber-Optic SFP Modules Connecting to SFP ModulesLC connector 19 Connecting to a 1000BASE-T SFP Module Connecting to 1000BASE-T SFP Modules20 Connecting to a Dual-Purpose Port Connecting to Dual-Purpose PortsWhere to Go Next Check Switch Post Results Diagnosing ProblemsThis section includes these troubleshooting topics Ethernet and Fiber Cables Check Switch LEDsCheck Switch Connections Bad or Damaged CableSpanning Tree Loops SFP Module Port IssuesPort and Interface Settings Ping the End DeviceAutonegotiation and NIC Cards How to Clear the Switch IP Address and ConfigurationCheck Switch Performance Speed, Duplex, and AutonegotiationSerial Number Location on the Cisco ME 3400G-2CS Switch Locating the Switch Serial NumberSerial Number Location on the Cisco ME 3400G-2CS Switch These sections describe the connectors used with the switch Connector Specifications10/100 Ports Figure A-1 10/100 Port Pinouts Dual-Purpose Ports Figure A-2 Fiber-Optic SFP Module LC ConnectorSFP Module Cable Specifications Cable and Adapter SpecificationsTwo Twisted-Pair Cable Pinouts Crossover Cable and Adapter Pinouts Four Twisted-Pair Cable Pinouts for 1000BASE-T PortsIdentifying a Crossover Cable TxD RxD Adapter PinoutsRxD TxD Switch Console RJ-45-to-DB-25 Port DTE This appendix lists the switch technical specifications Technical SpecificationsAC Power Requirements Physical Dimensions OL-7677-04 Connecting to DC Power Preparing the Ground Wire Grounding the SwitchReview these safety warnings before you ground the switch Figure C-1 Stripping the Ground Wire Figure C-3 Torquing Ground-Lug Screws Torque to 15 lbf-inTelco rack Grounding wire Connecting the Grounding Wire to Earth GroundTelco rack Primary power feed Secondary redundant power feed Wiring the DC-Input Power SourceCisco ME 3400G-12CS Switches Cisco ME 3400-24TS SwitchesAll Cisco ME 3400 Switches Figure C-8 Terminal Block Plug Console Figure C-11 Inserting Wires in the Terminal Block Plug Figure C-13 Completed Wiring of Terminal Block Plug OL-7677-04 Starting the Terminal-Emulation Software Accessing the CLI Through the Console PortIP Settings Entering the Initial Configuration InformationCompleting the Setup Program Switch or as a standalone switch Enter an enable secret password, and press ReturnEnter an enable password, and press Return Enter a virtual terminal Telnet password, and press ReturnThese choices appear Numerics Auto-MDIX Pinouts See also connectors and cables cautionsConnectors and cables 10/100 ports Console port Cisco IOS command-line interface CiscoViewConnecting outside the building warning Connection proceduresIN-3 Installing SFP modules 2-17 toConnectors LEDs Running at power on Power Connecting to ACConnecting to DC Power onIN-5 Ground connectionIN-6
Related manuals
Manual 10 pages 3.76 Kb

ME 3400 specifications

Cisco Systems ME 3400 Series is a robust family of Ethernet access switches designed specifically for service provider environments. These switches are engineered to deliver excellent performance, reliability, and flexibility, making them ideal for deploying Layer 2 and Layer 3 services to residential and business customers.

One of the prominent features of the ME 3400 series is its support for advanced Ethernet technologies. It provides extensive support for both traditional and modern Ethernet services, including Carrier Ethernet. With features such as Ethernet Operations, Administration, and Maintenance (EOAM), the ME 3400 aids in managing network performance and troubleshooting issues effectively. This capability ensures that service providers can deliver high-quality services and maintain optimal network health.

The ME 3400 series includes various models that support a range of port configurations, enabling scalability and adaptability to different network needs. This includes support for both Fast Ethernet and Gigabit Ethernet interfaces. The switches can accommodate multiple speed configurations, making them versatile for diverse deployment scenarios, from small businesses to large enterprise networks.

Another key characteristic of the ME 3400 is its integrated support for resilient Ethernet technologies, such as EtherChannel, Spanning Tree Protocol (STP), and Rapid Spanning Tree Protocol (RSTP). These technologies enhance redundancy and improve network reliability, crucial for service providers who require minimal downtime and high service availability.

Security is a top priority for service providers, and the ME 3400 series addresses this with extensive security features. It supports VLANs for traffic segmentation, access control lists (ACLs) for traffic filtering, and DHCP snooping to prevent unauthorized access to the network. These security measures ensure that both consumer and enterprise traffic remains isolated and secure.

Additionally, the ME 3400 series supports IPv4 and IPv6 routing, offering flexibility for service providers to cater to a broad customer base. The ability to manage both protocols ensures that networks can evolve seamlessly as internet traffic transitions to IPv6.

With energy efficiency increasingly becoming a concern, Cisco has integrated power-saving features into the ME 3400 series. These switches support Energy Efficient Ethernet (EEE) technology, which reduces power consumption during periods of low traffic, helping service providers to reduce operational costs.

In summary, the Cisco ME 3400 series is a versatile platform rich in features that streamline service delivery while ensuring high performance, security, and energy efficiency. It is an ideal choice for service providers looking to enhance their Ethernet services and meet evolving customer demands.