Cisco Systems DS Series manual Quick Start DS71-MD4 Module, Power, Serial Setup

Page 6

DS71-MD4 Serial host and 56k Modem

Power

CAUTION: This unit is intended for indoor use only. Do not install near water or expose this unit to moisture. To prevent heat buildup, do not coil the power cord when in use. Do not use extension cords. Do not attempt to make any internal changes to the power source. Do not attempt to modify any portion or component of a DS-Series Data Switch unless specifically directed to; as in Appendix E of this manual. BayTech must perform any internal changes.

CAUTION: High-voltage surges and spikes can damage this equipment. To protect from such power surges and spikes, this unit must have a good earth ground. A grounding screw connection is located near the power switch on the back of the unit.

CAUTION: Before removing or replacing any modules, turn off main power switch located on the DS- Series Base Unit. Communication to the DS-Series Data Switch will be disrupted while power is off.

QUICK START: DS71-MD4 Module

by Bay Technical Associates

For those Administrators who have requested the bare minimum for this type of equipment, follow these steps exactly. If this is a new unit shipped directly from Baytech, follow the steps. If this is a previously own unit, perform a factory reset to clear out any users and passwords still in the unit.

Serial/Modem Configuration:

1.Connect the 9FRJ45PC-4 or 9FRJ45PC-1 adapter to your PC.

2.Connect the supplied rollover flat cable RJ08X007 to the adapter and to the EIA232 serial port on the Baytech DS71-MD4 Module.

3.Use terminal emulation software to access the unit, (i.e. Microsoft Hyper-terminal). Set the PC serial port configuration to the following: 9600 bps, 8 data bits, 1stop bit and no parity.

4.If you get only a blinking cursor Press ‘Enter’. If still only a blinking cursor, Type 5 semi-colons (;),The Attention Character will not echo on the screen. There is a one second delay before the menu is displayed. You should see a menu similar to (Figure 1).

5.Select ‘C’ for the configuration menu.

6.Select the DS71-MD4 module. You should see a menu similar to (Figure 2).

7.Select the number for ‘Login Setup’ option. You should see a menu similar to (Figure 3).

8.Select the number for ‘Manage Users’ option. You should see a menu similar to (Figure 4).

9.NOTE: The ‘admin’ user can not be deleted.

10.Select ‘A’ to add user. Type the name and password at the prompts.

11.Press ‘Enter’ until get to the ‘Login Setup Menu’ (Figure 3).

12.Select option ‘Access Control’ to enable or disable the Modem and Serial Login Prompts.

13.Press ‘Enter’ until get to the ‘Login Setup Menu’ (Figure 3).

14.Select option ‘Assign User Ports’ (Figure 5).

15.Select the user and add the ports.

16.Press ‘Enter’ until you get the Configuration menu (Figure 2).

17.Select ‘Serial Port Configuration’ and set up the modem configuration.

At this point you have setup enough basic configurations to operate this Baytech unit.

Serial Setup

Connect the 9FRJ45PC-4adapter to the user’s computer

6

Image 6
Contents DS Series Manual Page DS71-MD4 Serial host and 56k Modem EIA-232 Serial ConnectionConnection Description Installation EIA-232 Serial ConnectionPower Serial SetupQuick Start DS71-MD4 Module Main Menu Following Header and Menu appears or similarAccess Control HeaderMenu Dial-Back Number DS71-MD4 Serial host and 56k Modem Manage UsersAuto Connect Assign User PortsCabling RJ-45 Cables and AdaptersDS71-MD4 Serial host and 56k Modem Adapters Signals Signal RS-232 COM Port Port DS Port RPC DE-9 Pin DB-25 PinAdapters RJ08X007 Detailed Operation and Configuration Configuration MenuDS71-MD4 Main Menu Configuration Status RTS Serial Port Configuration Baud RateWord Size Stop Bits ParityPort Device Name Port Select CodeRTS/DTR Line Driver Inactivity State Disconnect Timeguard Login SetupDefault setting is Disabled Connect port ID EchoHeader Delete User Change User’s PasswordADD User Change UserAuto Connect Add ports Remove PortsAdd All Ports Local Modem Option Remove All PortsUnit Reset TroubleshootingModules Reset Functional SolutionsNo Ports displayed for User Password not WorkNo Access to Configuration Menu Verify DS-chassis, Host Module, and DS74 is functioningBayTech Product Warranty DS71-MD4 Reset ProcedureTechnical Support ExceptionsReturn Authorization Process

DS Series, DS71-MD4 specifications

Cisco Systems DS71-MD4 and the DS Series represent a significant leap in the realm of network solutions, catering to an array of businesses seeking to optimize their connectivity and operational efficiency. This product line is designed to meet the diverse needs of modern enterprises, offering an amalgamation of advanced features, robust technologies, and exceptional characteristics.

One of the standout features of the DS71-MD4 within the DS Series is its impressive scalability. Designed for high-performance networking, it supports a vast number of users and devices, making it highly suitable for large organizations. This scalability ensures that companies can expand their networks without the need for a complete infrastructure overhaul.

At the heart of the DS71-MD4 are cutting-edge technologies that enhance both performance and security. The system is equipped with Cisco's proprietary security protocols, delivering peace of mind by protecting sensitive data against potential threats. The integration of advanced encryption standards ensures that communications remain secure, providing businesses with the utmost confidence in their network's integrity.

The DS Series also boasts exceptional reliability and uptime, features that are paramount for mission-critical applications. With redundant components and failover mechanisms, the DS71-MD4 minimizes the risk of downtime, allowing organizations to operate smoothly without disruption. Furthermore, the device supports various management tools that facilitate seamless integration into existing network infrastructures.

Another characteristic worth noting is the DS71-MD4's user-friendly interface, which allows network administrators to monitor and manage the system with ease. The intuitive design and accessibility of management tools empower IT teams to address issues promptly, fostering a proactive approach to network management.

Energy efficiency is another hallmark of the DS Series. By employing power-saving technologies, the DS71-MD4 minimizes energy consumption, enabling organizations to reduce operational costs and adhere to sustainable practices. This commitment to environmental responsibility aligns with the growing trend of eco-conscious business operations.

In conclusion, the Cisco Systems DS71-MD4 and the broader DS Series stand out as innovative solutions that blend performance, security, and sustainability. Their ability to adapt to evolving business needs while ensuring high availability and security makes them a compelling choice for enterprises looking to enhance their network infrastructures in today's fast-paced digital landscape.