Cisco Systems Superx Series manual System Management, Element Security Options, Physical Design

Page 9

System Management

IronView Network Manager (INM)

Web-based Graphical User Interface

Embedded Web Management

Industry Standard Command Line Interface (CLI)

RMON HP OpenView for Sun Solaris

HP-UX, IBM’s AIX, and Windows NT

Virtual Cable Tester

Repeater MIB

Element Security Options

Authentication, Authorization, and Accounting (AAA)

RADIUS

Secure Shell (SSHv2)

Secure Copy (SCP)

TACACS/TACACS+

Username/Password (Challenge and Response)

Bi-level Access Mode (Standard and EXEC Level)

Protection for Denial of Service attacks, such as TCP SYN or Smurf Attacks

Physical Design

ETSI ETS 300 119-4, Engineering Requirements for Sub-racks in misc. racks and cabinets

ANSI/EIA-310-D, Cabinets, Racks, Panels, and Associated Equipment

Dimensions

FastIron SuperX and

10.4” (H) x 17.5” (W) x 17.3” (D)

FastIron SX 800

26.3 cm (H) x 44.5 cm (W) x 43.8 cm (D)

 

FastIron SX 1600

24.5” (H) x 17.5” (W) x 17.3” (D)

 

62.2 cm (H) x 44.5 cm (W) x 43.8 cm (D)

Weight (Fully Loaded)

 

FastIron SuperX and

70 lbs (31 kg)

FastIron SX 800

 

FastIron SX 1600

196 lbs (88.6 kg)

Environmental

 

Operating temperature: 0ºC to 40ºC (32ºF to 104ºF)

Relative humidity: 5 to 90%, @40ºC (104ºF, non condensing)

Operating altitude: 6600 ft (2,000 m)

Storage temperature: -25ºC to 70ºC (-13ºF to 158ºF)

Storage humidity: 95% maximum relative humidity, non-condensing

Storage altitude: 15,000 ft (4,500 m) maximum

MTBF

Chassis

• SuperX Chassis, Fan Tray, 1 P/S: 269,386 hrs

 

• SX 800 Chassis, Fan Tray, 1 P/S: 142,786 hrs

 

• SX 800 Chassis, Fan Tray, 2 P/S: 230,584 hrs

 

• SX1600 Chassis, Fan Tray, 2 P/S: 99,908 hrs

 

• SX1600 Chassis, Fan Tray, 4 P/S: 213,865 hrs

Management Modules

• IPv4 Management Module with no optics:

 

287,664 hrs

 

• IPv4 Management Module, Zero ports:

 

534,522 hrs

 

• IPv4 Management Module, 2x10-GbE ports:

 

269,436 hrs

 

• IPv6 Management Module, 256MB SDRAM,

 

no optics: 292,557 hrs

 

• IPv6 Management Module, 512MB SDRAM,

 

no optics: 287,425 hrs

 

• IPv6 Management Module, 2x10GbE,

 

no optics: 304,109 hrs

Interface modules (IPv4

24-port 10/100/1000 Copper Module:

and IPv6 versions)

352,103 hrs

 

24-port SFP Module: 348,204 hrs

 

2-port 10-GbE Module: 464,938 hrs

Power Requirements

System Power Supply

-40-60 VDC Consumption (Amps): 36A

(SX-ACPWR, SX-DCPWR)

• 100 – 120 VAC Consumption (Amps): 14.3A

 

• 200 – 240 VAC Consumption (Amps): 7.2A

 

• AC Frequency: 50 – 60Hz

 

• Max BTU: 4874 BTU/Hr

 

• Max Watts (Output): 1200W

 

• Max Watts (Input): 1428W

1250W PoE Power Supply

• 100 – 120 VAC Consumption (Amps): 14A

 

• 200 – 240 VAC Consumption (Amps): 7A

 

• AC Frequency: 50 – 60Hz

 

• Max BTU: 4736 BTU/Hr

 

• Max Watts (Output): 1250W

 

• Max Watts (Input): 1388W

2500W PoE Power Supply

• 200 – 240 VAC Consumption (Amps): 14A

(SX-ACPWR-2500-POE)

• AC Frequency: 50 – 60Hz

 

• Max BTU: 9471 BTU/Hr

 

• Max Watts (Output): 2500W

 

• Max Watts (Input): 2775W

Safety Certifications

CAN/CSA-C22.2 No. 60950-1-03

Information Technology Equipment

Safety—Part 1: General Requirement

UL 60950-1, Information Technology Equipment—Safety— Part 1: General Requirement

EN 60950-1, Information Technology Equipment—Safety— Part 1: General Requirement

IEC 60950-1, Information Technology Equipment—Safety— Part 1: General Requirement

EN 60825-1, Safety of Laser Products. Equipment Classification,

Requirements and User Guide

EN 60825-2, Safety of Laser Products, Safety of Optical Fibre Communications Systems

Environmental Regulatory Compliance

RoHS Compliant (5 of 6)

WEEE compliant

Electromagnetic Emission Certifications

ICES-003, Electromagnetic Emission

FCC Class A

EN 55022/CISPR 22 Class A

VCCI Class A

EN 61000-3-2, Power Line Harmonics

EN 61000-3-3, Voltage Fluctuation and Flicker

EN 61000-6-3, Electromagnetic Compatibility

AS/NZS CISPR 22, Electromagnetic Compatibility

Immunity

EN 61000-6-1, Electromagnetic Compatibility, Generic Standard

EN 55024, Immunity Characteristics Supersedes:

EN 61000-4-2, ESD

EN 61000-4-3, Radiated, Radio Frequency, Electromagnetic Field

EN 61000-4-4, Electrical Fast Transient

EN 61000-4-5, Surge

EN 61000-4-6, Conducted Disturbances Induced by Radio

Frequency Fields

EN 61000-4-8, Power Frequency Magnetic Field

EN 61000-4-11, Power Frequency Magnetic Field

Mounting Options

• 19” Universal EIA (Telco) Rack or Tabletop

Image 9
Contents Brocade Fastiron Primary Features and Benefits FastIron SuperXFastIron SX Intelligent and Scalable Power Over Ethernet PoE Advanced QoS and Low Latency for Enterprise ConvergenceEase of Use Plug and Play Complete Solution for Multicast and Broadcast Video Flexible Bandwidth ManagementComprehensive Security Suite Resilient Design Ensures Business Continuity Deployment of IPv6 Capable HardwareFuture-Proofing the Network Through IronShield Advanced Security Advanced Quality of Service System and Network ResilienceIPv6 Futureproofing Quality of Service Brocade Fastiron SuperX SpecificationsIeee Standards Compliance RFC ComplianceWeight Fully Loaded DimensionsPower Requirements Safety CertificationsFeature FastIron SuperX FastIron SX System summaryXFP Part Number Description Ordering InformationIPv6-Capable Ordering Information Warranty