Cisco Systems SFS 7024 manual Electrical Safety Precautions

Page 28

Chapter

Precautions for Rack-Mountable Products

Warning Installing system components in a rack without the front and side stabilizers installed could cause the rack to tip over. Therefore, always install the stabilizers before installing components in the rack.

Warning After installing system components in a rack never pull more than one component at one time out of the rack on its slide assemblies. The weight of more than one extended component could cause the rack to tip over.

Warning Do not step on or stand on any component when servicing other components in a rack.

Warning The chassis, when fully populated with leaf modules, spine modules, power and fan supplies, is very heavy (approximately 175 lbs.). It is recommended that a lifting device be used to handle a fully loaded chassis.

Caution Always load the rack from the bottom up, loading the heaviest item first.

Caution Make sure the rack is level and stable before extending any component from the rack.

Note Ensure that proper airflow is provided to components of the rack.

Protecting Against Electrostatic Discharge

Caution

Caution

Use a grounded wrist strap designed to prevent static discharge.

Static electricity can harm delicate components inside the system. To prevent ESD damage, users need discharge any static electricity from their bodies before touching any electronic components. Touching an unpainted metal surface will discharge static electricity.

Caution When transporting an ESD sensitive component, first place it in an antistatic container or packaging.

Electrical Safety Precautions

Warning Do not work alone when working with high voltage components.

Cisco SFS 7024 Hardware Users Guide

2-12

OL-8794-02

 

 

Image 28
Contents Cisco SFS 7024 Hardware Installation Guide Page Preface Audience Connect Equipment to the Ports and Power On the System Snmp Configuring the Switch Default Gateway IP Address Fix Fan C-86 Contents Cisco SFS 7024 Hardware Users Guide New and Changed Information Viii Audience OrganizationConventions Related DocumentationObtaining Documentation Cisco.comDocumentation Feedback Obtaining Technical AssistanceOrdering Documentation Cisco Technical Support WebsiteSubmitting a Service Request Definitions of Service Request SeverityObtaining Additional Publications and Information Xiv SFS 7024 Feature Set Key Design FeaturesStrategic Benefits A P T E RSFS 7024 Product Specifications Mechanical/Thermal/Power SpecificationsThermal Management Features Power Design FeaturesChassis Viewer Software Chassis Viewer FunctionalitySubnet Manager SFSSubnet Management InfiniBand General Services Managers and AgentsSubnet Management Agents Snmp Support Snmp MIBsCommunications Manager CM Baseboard Manager BM and Baseboard Management Agent BMAInstallation Planning the Installation Environmental RequirementsInstalling and Routing Cable Rack Specifications and RecommendationsAssembly 90-Degree Bend Radii Power Supply Power RequirementsUninterruptible Power Supply Installation Tasks Checklist Safety InformationElectrical Safety Precautions Tools and Equipment Required Check the Installation Site Unpack the EquipmentInstallation Tasks Install the Rails in the RackMounting Hardware Kit Contents Mounting KitInstalling the Switch Face Plate Rack-Mount the SwitchInstalling the Spine and Leaf Modules SFS 7024 Chassis Spine Module Slot Numbering Removing a Module or Blank LeafConnect Equipment to the Ports and Power On the System SFS 7024 Chassis Front ViewLeaf Start-up Procedures Connecting PowerBringing Up the System For the First Time Spine 3 Unmanaged Fan Spine 2 Managed Spine 1 Managed Lower Hemisphere Upper HemisphereGet to a boot prompt by following Step a or b Inet on backplane b Verifying Start-up SFS 7024 Component LEDsChassis Status LED Power Supply LEDs Subnet Manager Agent SMA LEDRJ45 LEDs Fan LEDsSFS 7024 Leaf and Spine Module LEDs Leaf Module IB Port LEDsSpine and Leaf Module Status LED Spine and Leaf Module Attention LEDAccessing On-line Help 10 Chassis Viewer Online Help ButtonsShutdown Procedures Rebooting Components from Chassis ViewerHot Swapping Components Rebooting Multiple Managed SpinesHot Swapping Spine and Leaf Modules Hot Swapping Power Supplies Hot Swapping the Fan UnitChassis Viewer Chassis Viewer Manages? Help Button HomeSupport Button Displaying the Leaf and Spine Module Views Leaf Module ViewSpine Module View Leaf Module ViewLeaf and Spine Module Component Details Area Leaf and Spine Details HeaderLeaf and Spine Information Area ApplyDisplaying the Chassis View 11 Leaf Module Chassis MouseoverChassis View Component Details Area Chassis Details Header15 Reboot Window Chassis View Component Information Area Tabs Chassis View Component Information AreaLEDs and Sensors Tab System Tab Power Tab Chassis FRU TabFan Tab Modifying Switch Component InformationBackplane Tab Chassis View Menu Configuration and Monitoring FeaturesLogging Set Level 20 Logging Submenu23 Device Tab Software Module Configurator Preset Tab 24 Log System Configurator Preset TabConfigure Syslog on a Linux Server Reset Log LevelsSyslog Tab Firmware Update 27 Reset Log Levels WindowTarget Configuration Select Target ConfigurationTarget Configuration Window Field Descriptions Snmp Target AddressesSnmp Target Parameters Filter Status 33 Filter Status ButtonSetting Community Strings 34 Filter Status ScreenChassis Traps 36 Set Community Strings WindowIcsChassisTrapSystemReboot IcsChassisTrapSystemSwitchFailoverIcsChassisTrapModuleBulkPowerFailure IcsChassisTrapModuleRebootIcsChassisTrapPowerSupplyInserted IcsChassisTrapPowerSupplyRemovedIcsChassisTrapPowerSupplyFailed IcsChassisTrapPowerSupplyEEPROMReadFailureInterswitch Link ISL Ports SFS 7024 Port StatisticsUnderstanding Port Naming Conventions Leaf modules/portsPort Statistics Field Descriptions InfiniBand StatisticsSymbol Errors Link Error RecoveryReceive Errors Remote Physical Error ReceivedLeaf Modules Leaf and Spine Module IB Port StatisticsSpine Modules Set Field Thresholds 44 Spine Port Statistics WindowPortXmitDataThresh PortRecvDataThreshPortXmitPktsThresh PortRecvPktsThreshTime Service 47 Switch Time Service Click the Use Network Time Protocol? checkboxTime Zone Tips Daylight Saving Time TipsConfiguring the Switch Default Gateway IP Address Configuring the Switch OOB IP AddressFrom the OOB LAN IP submenu, click Set Default Gateway IP Type in the correct switch default gateway IP address Spine View Menu Viewing the LogSelect Edit, Copy or Ctrl + C Purging the LogSelect Edit, Paste or Ctrl + Select Boot Image License Keys Key AdministrationAdding a New License Key Deleting a License KeyClick OK to delete Technical Specifications Appendix Cisco SFS 7024 Hardware Users Guide Overview AdministratorOperator Commands and Functional Groups Online Help Accessing the CLIKeyboard Shortcuts General Groups and CommandsFirmware IbSwitchInfo ChassisKeyManagement LogTimeManagement Capture DeprecatedAppendix Cisco SFS 7024 Hardware Users Guide Switch Power SupplyProblem Fix Hardware ChecksFan SFS 7024 Leaf Module IB Ports Problem FixOOB Ethernet RJ45 Port Troubleshooting Scenarios InfiniBandInvalid IP Address entered for SWC via Console Port Bad IB CableAppendix Cisco SFS 7024 Hardware Users Guide

SFS 7024 specifications

Cisco Systems SFS 7024 is a high-performance, scalable storage solution designed to meet the demanding needs of modern data-driven enterprises. Generally recognized for its reliability and efficiency, the SFS 7024 stands out in environments where performance, availability, and scalability are paramount.

One of the main features of the SFS 7024 is its ability to support high-speed data transfers, making it suitable for applications that require rapid access to large datasets. The system leverages advanced networking technologies, including InfiniBand, to achieve impressive throughput and low-latency communication between storage nodes. This technology ensures that data can be accessed quickly, which is crucial for applications such as high-performance computing, big data analytics, and virtualized environments.

The architecture of the SFS 7024 incorporates a clustered design that allows for easy expansion. Businesses can start with a smaller configuration and scale up as their storage needs grow. This modularity reduces the risk of over-provisioning and helps organizations manage their budgets effectively. The system supports both file and block storage, providing flexibility in how data is stored and accessed.

Another significant characteristic of the SFS 7024 is its robust data protection features. With built-in redundancy and automatic failover capabilities, the system ensures continued operation even in the event of hardware failures. Data integrity is maintained through advanced error correction protocols, enhancing the overall reliability of the storage solution.

Cisco also integrates powerful management tools with the SFS 7024. The system's management interface allows administrators to monitor performance metrics, manage resources, and configure settings from a centralized location. This simplifies daily operations and reduces the complexity of managing large storage environments.

In summary, Cisco Systems SFS 7024 is a distinguished storage solution characterized by its high-speed performance, modular scalability, and robust data protection features. With its innovative technologies and user-friendly management capabilities, it serves as an ideal choice for enterprises looking to enhance their storage infrastructure. Whether dealing with intensive data workloads or seeking a dependable storage system, organizations can rely on the SFS 7024 to meet their evolving needs.