Cisco Systems Cisco Small Business Integrated Security Appliances: ISA500 Series Overview

Page 8

Rack Mounting

You can mount the security appliance in any standard size, 19-inch (about 48 cm) wide rack. The security appliance requires 1 rack unit (RU) of space, which is 1.75 inches (44.45 mm) high. The rack-mounting kit is included with the unit.

CAUTION Do not overload the power outlet or circuit when installing multiple devices in a rack.

STEP 1 Place one of the supplied silicon rubber spacers on the side of the security appliance so that the four holes align to the screw holes. Place the rack mount bracket next to the silicon rubber spacer and install the M3 screws.

STEP 2 Install the security appliance into a standard rack as shown below. Place the washers on the brackets so that the holes align to the screw holes and then install the M5 screws.

Step 2

Step 1

 

Connecting the Cisco ISA500 Series

4

Integrated Security Appliances

281985

STEP 1 If you are installing the ISA550W or ISA570W, screw each antenna onto a threaded connector on the back panel. Orient each antenna to point upward.

STEP 2 Connect the security appliance to power using the supplied power cord and adapter. Make sure that the power switch is turned off.

8

Cisco ISA500 Series Integrated Security Appliances Quick Start Guide

Image 8
Contents Quick Start Guide Default Settings Parameter Default ValueWelcome Before You BeginGetting to Know the Cisco ISA500 Series Integrated Security AppliancesProduct Models Front PanelISA570 Front Panel ISA570W Front PanelFront Panel Lights Light DescriptionBack Panel ISA550 and ISA550W Back PanelISA570 and ISA570W Back Panel SpeedPlacement Tips Back Panel Descriptions FeatureMounting the Cisco ISA500 Series ANT01/ANT02Wall Mounting Connecting the Cisco ISA500 Series Rack MountingGetting Started with the Configuration Suggested Next Steps Where to Go From Here SupportProduct Documentation Cisco Small Business78-19625-01