Emulex 355 manual Features, Inspeed Technology

Page 5

INSPEED™ SAN STORAGE SWITCH MODEL 355

CHAPTER 1 INTRODUCTION

USERS GUIDE

 

FEATURES

The InSpeed™ SAN Storage Switch Model 355 has the following features:

High Performance Fibre Channel Switching:

Wire speed non-blocking Crossbar switch core

Single 12-port InSpeed SOC 320 ASIC with embedded SERDES

Multiple simultaneous conversations between ports

Traffic routed directly to destination ports

2 Gb/s or 1 Gb/s performance across all ports

Aggregate bandwidth of 48 Gb/s

Supports cascades up to 3 switches and up to 126 host and storage devices

No complex fabric services or buffers

Effortlessly connects to any vendor’s fabric

Patent-pending technology:

Fairness and Prioritization–ensures devices all have guaranteed access, or explicitly have prioritized access, over all other devices in a system.

StealthTM Intelligent Change Manager–delivers maximum stability through automatic elimination of state and change notification system disruptions and unprecedented control of disruptive events.

Automatic Trunking–enables fully-multiplied throughput and bandwidth, failover pathing, and dynamic load balancing and device prioritization.

Advanced diagnostics, performance monitoring, and fault isolation including continuous switch and port monitoring and automatic bypass of problematic or unused ports.

Port Smart Settings, which are predefined port-level configurations that optimize switch performance and stability.

One-Step Zoning, including overlapping/non-overlapping zones with port or AL_PA-based zoning.

Switch management using the embedded http-based web server, Command Line Interface (CLI), or Simple Network Management Protocol (SNMP).

Half-rack, 1U size for easy installation (optional 19" rack-mounting kits available).

Fibre Channel ANSI Standards Compliance

INSPEED™ TECHNOLOGY

InSpeed™ technology is an advanced switching architecture that couples a non-blocking crossbar switch with a unique switch port logic and per-port SERDES. This results in the industry’s highest density Fibre Channel switch on a chip (SOC). The port logic is based on Fibre Channel-Arbitrated Loop (FC-AL), an ANSI standard (X3T11) designed to provide shared bandwidth over low-cost media.

This architecture enables the switch’s router to send data directly from one port to another, allowing for multiple, simultaneous conversations between ports—effectively multiplying bandwidth. InSpeed™ provides the same performance as complex fabric switches that support FC-SW2. InSpeed™ can even exceed fabric switch performance in entry-level SAN environments, where the overhead associated with longer name addressing and services is not beneficial.

2

Image 5
Contents InSpeedTM Model Inspeed SAN Storage Switch Model USER’S Guide Table of Contents Overview IntroductionInspeed Technology FeaturesStorage Consolidation and Shared Storage Pooling Switch ApplicationsTape Library Consolidation Depicts a sample tape library consolidation configurationServer Clustering Rich MediaTo unpack the switch Installation PreparationRack Installation Desktop InstallationSwitch Installation To place the switch on a desktopUL Guidelines for Mounting Equipment in a Rack Ethernet LEDs Switch LedsSystem LEDs Ethernet LEDs IndicationSystem LEDs Indication Port LEDsSFP Status Port Bypassed Green LED Yellow LEDAttaching a Device to the Switch Installing an SFPRemoving an SFP SFP CompatibilityTo boot the switch and SAN Booting the Switch and SANSwitch Management To connect through a serial interface Configuring the Network InterfaceGetting Started Command Button Description Connecting to the Web ManagerWeb Manager Overview To connect to the Web ManagerTo download firmware Click Help Downloads DocumentationLog in to the Switch Initial Switch SetupChange the Password To log in to the switchTo view the current date and time Click Switch Date & Time Change the Switch NameTo set the date and time settings To change the switch name Click Switch ConfigurationTo… Click… This guide, see Managing the SwitchFrequent Switch Configuration Tasks Configuring the Switch Settings Logging in to the SwitchTo change a switch setting To reset the switchSwitch Identification General Switch SettingsSetting Description Network LocationVersion Information Switch SpeedBlocking ARB Agent Up TimeState Description Setting Snmp TrapsTo configure an Snmp trap To synchronize time with the host system Click Host Time Configuring Date and Time SettingsTo change the time Click Switch Date & Time Opening a Telnet Session Changing the PasswordTo change switch thresholds or time intervals Adjusting the Switch ThresholdsTo view the Port Smart Settings Click Port Smart Settings Configuring the Port Smart SettingsDefault Smart Settings To assign a Smart Setting to one or more ports Creating Custom Smart SettingsTo set all ports to the currently selected Smart Setting To create a custom Smart SettingTo modify a custom Smart Setting Smart Setting AssignmentsTo rename a custom Smart Setting To delete a custom Smart SettingPort Information Pre-Insertion TestingStealth Intelligent Change Change NotificationsManager Change Notification onPort Recovery Diagnostics Managing Firmware and Configuration FilesPort Control Bypass on Clock DeltaSwitch Configuration Files Switch Firmware FilesOne-Step Zoning Restoring the Factory Default SettingsTo restore the factory default configuration To add ports to a zone Color DescriptionTo activate zoning To remove a port from a zone13 Devices in a Single Zone Single-Switch ZoningTo add storage devices to multiple zones Adding Devices to Multiple Zones16 Ports in Multiple Zones on the One-Step Zoning Multiple Switch ZoningAlpa Zoning Recovering a Bad Zone AutomaticallyTo set up Hard Zoning Connecting Ports Through Hard ZoningTree Cascades Cascading SwitchesString Cascades 22 Automatic Trunking example Automatic Trunking24 Load Balancing Across Multiple Cascade Ports Load BalancingFairness and Prioritization Load IndicatorsTo change the load balancing settings Monitoring the Switch Viewing Switch StatusSwitch Information Status IndicatorsBar Color Indication Port Utilization and HealthPort Color Indication To export the event log To view the event log Click Switch Event LogViewing the Event Log Field Description Viewing Port InformationTo view port information Click Port Information Value Description Viewing Port UtilizationTo change the port utilization interval To view port utilization Click Port UtilizationStatistic Description Viewing Port DiagnosticsTo reset a port Click Advanced Functions Diagnostics Port To save diagnostic informationManual Port Operation To clear the countersDetection Indication Viewing Ordered SetsF7 Initialization CRC ErrorChange Notification UnknownProblem Recommended Action Troubleshooting Device ConnectionsOperational Condition Recovery Troubleshooting Management ConnectionsPort Bypass Conditions and Recovery Default Smart Setting Attributes Fibre Channel References Appendixes Requirement Value Switch SpecificationsOperating Conditions Logging in and OUT Connecting to the CLITo connect through a network interface To log in to the CLIFrequent Switch Configuration Tasks Using the CLICLI Commands Event Event Message Severity Severity Description LevelDBG Hex Decimal Arbitrated Loop Physical AddressesPhysical Address Alpa or Arbitrated LoopArbitration Current Fill WordIndex SFP Zoning 36 , 38 , 39
Related manuals
Manual 72 pages 33.15 Kb

355 specifications

The Emulex 355 is a high-performance network interface card (NIC) designed specifically for data centers requiring advanced connectivity, reliability, and speed. With the rapid evolution of data transmission technology, the Emulex 355 stands out due to its robust features and capabilities that cater to the demands of modern IT infrastructures.

One of the key features of the Emulex 355 is its support for 10 Gigabit Ethernet, which allows for significantly faster data transfer rates compared to standard Gigabit connections. This increased bandwidth is essential for handling large volumes of data traffic, particularly in virtualized environments and cloud computing applications. Its high throughput ensures that data can be transmitted rapidly across networks, minimizing latency and improving overall performance.

The Emulex 355 employs advanced technologies such as iSCSI Offload and FCoE (Fibre Channel over Ethernet), which help enhance data processing efficiency. These technologies allow the card to offload processing tasks from the host system's CPU, reducing the load on server resources and optimizing performance. The result is a more efficient system that can handle more concurrent connections and processes without being overwhelmed.

In addition to speed and efficiency, reliability is paramount in data center operations. The Emulex 355 includes features like error detection and correction, ensuring data integrity during transmission. Built-in redundancy and failover capabilities safeguard against potential network disruptions, allowing for continuous availability of services—a crucial aspect in mission-critical environments.

The Emulex 355 also offers support for various robust networking protocols, enabling seamless integration into existing network infrastructures. Its compatibility with multiple operating systems and virtualization platforms, such as VMware and Microsoft Hyper-V, further enhances its versatility.

Another notable characteristic of the Emulex 355 is its energy-efficient design. It is optimized for lower power consumption without sacrificing performance, aligning with contemporary efforts to reduce the carbon footprint in data centers.

In conclusion, the Emulex 355 NIC is a powerful solution equipped with features that address the complex demands of modern data centers. Its combination of speed, reliability, and efficiency, along with advanced technologies, makes it a preferred choice for organizations looking to enhance their network capabilities and ensure smooth, uninterrupted operations.