Emulex 355 manual Default Smart Setting Attributes

Page 61

INSPEED™ SAN STORAGE SWITCH MODEL 355

CHAPTER 4 TECHNICAL REFERENCE

USERS GUIDE

 

DEFAULT SMART SETTING ATTRIBUTES

 

Initiator or Target

Initiator with Stealth

Target with Stealth

Fabric Connection

Tree Cascade

String Cascade --Trunk 1

String Cascade --Trunk 2

String Cascade --Trunk 3

String Cascade --Trunk 4

 

 

 

 

 

 

 

 

 

 

Smart Setting

Initiator or

Initiator

Target with

Fabric

Tree

String

String

String

String

Name

Target

with Stealth

Stealth

Connection

Cascade

Cascade--

Cascade--

Cascade--

Cascade--

 

 

 

 

 

 

Trunk 1

Trunk 2

Trunk 3

Trunk 4

 

 

 

 

 

 

 

 

 

 

Smart Setting

Initiator or

Initiator or

Initiator or

Tree

Tree

String

String

String

String

Type

Target Port

Target Port

Target Port

Cascade

Cascade

Cascade 1

Cascade 2

Cascade 3

Cascade 4

 

 

 

 

 

 

 

 

 

 

Smart Insertion

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port Test Before

Enabled

Enabled

Enabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Insert Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stealth Intelligent

Off: No

Initiator:

Target:

Off: No

Switch-

Switch-

Switch-

Switch-

Switch-

Change Manager

Change

Only

Only Send

Change

Switch:

Switch:

Switch:

Switch:

Switch:

 

Protection

Receive

Changes

Protection

Send and

Send and

Send and

Send and

Send and

 

 

Changes

 

 

Receive

Receive

Receive

Receive

Receive

 

 

 

 

 

Changes

Changes

Changes

Changes

Changes

 

 

 

 

 

 

 

 

 

 

Change

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Notification on

 

 

 

 

 

 

 

 

 

Insertion Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Notification on

 

 

 

 

 

 

 

 

 

Removal Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bad Device

Disabled

Enabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Recovery Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear on Stall

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bypass on No

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Enabled

Activity Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bypass on OS

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Error Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bypass on CRC

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Error Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port Control

Auto

Auto

Auto

Auto

Auto

Auto

Auto

Auto

Auto

 

 

 

 

 

 

 

 

 

 

Bypass on Clock

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Delta Policy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

Image 61
Contents InSpeedTM Model Inspeed SAN Storage Switch Model USER’S Guide Table of Contents Overview IntroductionInspeed Technology FeaturesStorage Consolidation and Shared Storage Pooling Switch ApplicationsTape Library Consolidation Depicts a sample tape library consolidation configurationServer Clustering Rich MediaTo unpack the switch Installation PreparationRack Installation Desktop InstallationSwitch Installation To place the switch on a desktopUL Guidelines for Mounting Equipment in a Rack Ethernet LEDs Switch LedsSystem LEDs Ethernet LEDs IndicationSystem LEDs Indication Port LEDsSFP Status Port Bypassed Green LED Yellow LEDAttaching a Device to the Switch Installing an SFPRemoving an SFP SFP CompatibilityTo boot the switch and SAN Booting the Switch and SANSwitch Management Getting Started Configuring the Network InterfaceTo connect through a serial interface Command Button Description Connecting to the Web ManagerWeb Manager Overview To connect to the Web ManagerTo download firmware Click Help Downloads DocumentationLog in to the Switch Initial Switch SetupChange the Password To log in to the switchTo view the current date and time Click Switch Date & Time Change the Switch NameTo set the date and time settings To change the switch name Click Switch ConfigurationFrequent Switch Configuration Tasks Managing the SwitchTo… Click… This guide, see Configuring the Switch Settings Logging in to the SwitchTo change a switch setting To reset the switchSwitch Identification General Switch SettingsSetting Description Network LocationVersion Information Switch SpeedBlocking ARB Agent Up TimeTo configure an Snmp trap Setting Snmp TrapsState Description To change the time Click Switch Date & Time Configuring Date and Time SettingsTo synchronize time with the host system Click Host Time Opening a Telnet Session Changing the PasswordTo change switch thresholds or time intervals Adjusting the Switch ThresholdsTo view the Port Smart Settings Click Port Smart Settings Configuring the Port Smart SettingsDefault Smart Settings To assign a Smart Setting to one or more ports Creating Custom Smart SettingsTo set all ports to the currently selected Smart Setting To create a custom Smart SettingTo modify a custom Smart Setting Smart Setting AssignmentsTo rename a custom Smart Setting To delete a custom Smart SettingPort Information Pre-Insertion TestingStealth Intelligent Change Change NotificationsManager Change Notification onPort Recovery Diagnostics Managing Firmware and Configuration FilesPort Control Bypass on Clock DeltaSwitch Configuration Files Switch Firmware FilesTo restore the factory default configuration Restoring the Factory Default SettingsOne-Step Zoning To add ports to a zone Color DescriptionTo activate zoning To remove a port from a zone13 Devices in a Single Zone Single-Switch ZoningTo add storage devices to multiple zones Adding Devices to Multiple Zones16 Ports in Multiple Zones on the One-Step Zoning Multiple Switch ZoningAlpa Zoning Recovering a Bad Zone AutomaticallyTo set up Hard Zoning Connecting Ports Through Hard ZoningString Cascades Cascading SwitchesTree Cascades 22 Automatic Trunking example Automatic Trunking24 Load Balancing Across Multiple Cascade Ports Load BalancingTo change the load balancing settings Load IndicatorsFairness and Prioritization Monitoring the Switch Viewing Switch StatusSwitch Information Status IndicatorsPort Color Indication Port Utilization and HealthBar Color Indication Viewing the Event Log To view the event log Click Switch Event LogTo export the event log To view port information Click Port Information Viewing Port InformationField Description Value Description Viewing Port UtilizationTo change the port utilization interval To view port utilization Click Port UtilizationStatistic Description Viewing Port DiagnosticsTo reset a port Click Advanced Functions Diagnostics Port To save diagnostic informationManual Port Operation To clear the countersDetection Indication Viewing Ordered SetsF7 Initialization CRC ErrorChange Notification UnknownProblem Recommended Action Troubleshooting Device ConnectionsPort Bypass Conditions and Recovery Troubleshooting Management ConnectionsOperational Condition Recovery Default Smart Setting Attributes Fibre Channel References Appendixes Operating Conditions Switch SpecificationsRequirement Value Logging in and OUT Connecting to the CLITo connect through a network interface To log in to the CLIFrequent Switch Configuration Tasks Using the CLICLI Commands Event Event Message Severity Severity Description LevelDBG Hex Decimal Arbitrated Loop Physical AddressesPhysical Address Alpa or Arbitrated LoopArbitration Current Fill WordIndex SFP Zoning 36 , 38 , 39
Related manuals
Manual 72 pages 33.15 Kb

355 specifications

The Emulex 355 is a high-performance network interface card (NIC) designed specifically for data centers requiring advanced connectivity, reliability, and speed. With the rapid evolution of data transmission technology, the Emulex 355 stands out due to its robust features and capabilities that cater to the demands of modern IT infrastructures.

One of the key features of the Emulex 355 is its support for 10 Gigabit Ethernet, which allows for significantly faster data transfer rates compared to standard Gigabit connections. This increased bandwidth is essential for handling large volumes of data traffic, particularly in virtualized environments and cloud computing applications. Its high throughput ensures that data can be transmitted rapidly across networks, minimizing latency and improving overall performance.

The Emulex 355 employs advanced technologies such as iSCSI Offload and FCoE (Fibre Channel over Ethernet), which help enhance data processing efficiency. These technologies allow the card to offload processing tasks from the host system's CPU, reducing the load on server resources and optimizing performance. The result is a more efficient system that can handle more concurrent connections and processes without being overwhelmed.

In addition to speed and efficiency, reliability is paramount in data center operations. The Emulex 355 includes features like error detection and correction, ensuring data integrity during transmission. Built-in redundancy and failover capabilities safeguard against potential network disruptions, allowing for continuous availability of services—a crucial aspect in mission-critical environments.

The Emulex 355 also offers support for various robust networking protocols, enabling seamless integration into existing network infrastructures. Its compatibility with multiple operating systems and virtualization platforms, such as VMware and Microsoft Hyper-V, further enhances its versatility.

Another notable characteristic of the Emulex 355 is its energy-efficient design. It is optimized for lower power consumption without sacrificing performance, aligning with contemporary efforts to reduce the carbon footprint in data centers.

In conclusion, the Emulex 355 NIC is a powerful solution equipped with features that address the complex demands of modern data centers. Its combination of speed, reliability, and efficiency, along with advanced technologies, makes it a preferred choice for organizations looking to enhance their network capabilities and ensure smooth, uninterrupted operations.