Cabletron Systems TRMIM-24A, TRXI-22A manual REQUIREMENTS/SPECIFICATIONS TPIM-F2, Value Case Budget

Page 26

REQUIREMENTS/SPECIFICATIONS

TPIM-F2

The TPIM-F2 shown in Figure 2-6 is an ST connector that supports Multimode fiber Optic cabling.

RX

TX

LNK

 

 

 

 

TPIM-F2

Figure 2-6. The TPIM-F2

Note: The transmitter power levels and receive sensitivity levels given are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given to those measured on any particular port. If Power Levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed (i.e. -30.5 dBm peak=-33.5 dBm average).

Parameter

Typical

Worst

Worst Case Typical

Receive

Value

Case

Budget

Budget

 

 

 

 

Sensitivity:

-30.5 dBm

-28.0 dBm

Peak Input

 

 

 

 

Power:

-7.6 dBm

-8.2 dBm

Transmitter Power

 

 

 

50/125 ∝m

 

 

 

 

fiber:

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

62.5/125 ∝m

 

 

 

 

fiber:

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

100/140 ∝m

 

 

 

 

fiber:

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate:

Better than 10-10

 

 

Page 2-14

Image 26
Contents Cabletron SYSTEMS, P. O. Box 5005, Rochester, NH Printed On Recycled Paper FCC Notice Exclusion of Warranty and Disclaimer of Liability Installation Contents Table of Contents IntroductionREQUIREMENTS/SPECIFICATIONS Local Management ContentsTesting and Troubleshooting Using this Manual Chapter IntroductionIntroduction Getting Help Trxi Active Concentrator OverviewSpeed Fault Protection Trxi FeaturesCable Signal Polarity Active TCU PortsTpim Group Subgroup Section LCD and Reset ButtonRmon MIB Support COM Port ApplicationsIntroduction Remote Network Management Capabilities Recommended ReadingChapter REQUIREMENTS/SPECIFICATIONS Cable SpecificationsAttenuation and Impedance Frequency Impedance AttenuationType 3 Media Filters Maximum Lobe LengthsUTP Cable Type Maximum Lobe Length Mbps Maximum Number of StationsREQUIREMENTS/SPECIFICATIONS STP Cable Type Ring Speed Mbps Maximum Trunk LengthsSolution Mixed Cable TypesFiber Optic Budget Multimode Fiber Optic Cable Specifications for the TPIM-F2Cable Type Attenuation Maximum Drive Distance Single Mode Fiber Optic Cable Specifications for the TPIM-F3 Noise TemperatureCrosstalk REQUIREMENTS/SPECIFICATIONS Modem REQUIREMENTS/SPECIFICATIONS COM 1/COM 2 Port SpecificationsConsole UPSREQUIREMENTS/SPECIFICATIONS Tpim Specifications TPIM-T1REQUIREMENTS/SPECIFICATIONS TPIM-T2 TPIM-T4Value Case Budget REQUIREMENTS/SPECIFICATIONS TPIM-F2Parameter Typical Worst Worst Case Typical REQUIREMENTS/SPECIFICATIONS TPIM-F3 Parameter Typical Minimum Maximum Output Min. Load Max. Load Max Power REQUIREMENTS/SPECIFICATIONS General SpecificationsPower Supply Requirements Environmental RequirementsPhysical REQUIREMENTS/SPECIFICATIONS SafetyService Unpacking the Trxi Attaching the Strain Relief BracketInstalling the Trxi Attaching the Strain ReliefInstalling the Trxi in the Rack Rack Mounting the TrxiWall Mounting the Trxi Free-Standing Installation Installation Setting the Ring Speed Switch Ring Speed Switch SettingsInstallation Setting the Nvram Switch Installation Connecting the Trxi to the Power Source Connecting the Network Lobe Port CablingConfiguration Examples for TRXI-24A and TRXI-44A LNK TPIM-T4 Installation Installing the Tpim RI/RO Modules Setting the TPIM’s Phantom Switch and RI/RO Switch Top ViewInstalling a Tpim to the Trxi 12. Installing a TpimConnecting a Twisted Pair Segment to the TPIM-T1 Connecting a Twisted Pair Segment to the TPIM-T2 or TPIM-T4 Installation LNK Finishing the Installation Chapter Testing and Troubleshooting Checking the InstallationUsing Lanview LEDs TRXI-24ATOKEN Ring HUB with LanviewTesting and Troubleshooting Using the LCD Display LCDStatic System Messages Displayed Message CommentsAlarm Messages Displayed Messages CommentsNormal Unsaved Initialization Messages Failure or Error MessagesUnsaved Initialization Messages Saved System Messages Displayed MessageChapter Local Management Local Management Management Terminal Requirements Attaching the Management TerminalGeneral Setup Setting the Management Terminal Setup ParametersDisplay Setup SetupModem Cable Configuration and Setup RJ45 COM 2 PortLocal Management Accessing Local Management Trxi Local ManagementLocal Management Using Local Management Main MenuExiting Your Local Management Session Selecting a Menu OptionExiting a Local Management Screen System Time System Level ScreenSystem Date IP AddressCOM 2 Application Setting the System DateCOM 1 Application Clear All NvramSetting the System Time Setting the IP AddressSetting the Subnet Mask Setting the Clear All Nvram Field Setting the Enable Beacon Recovery FieldSnmp Community Names Screen Community Name AccessComponent Name Editing the Community Name FieldTrap Destination Enable TrapsSnmp Traps Screen Trap Community NameSetting Snmp Traps Ring Security Screen Stn Edit Security ModeStation Address Previousscreen SAVE/EXECUTENextscreen ReturnBuilding the Allowed List Adding Stations to the Station Address Allowed ListChanging the Ring Security Mode Deleting Stations from the Station Address Allowed ListInterface Device Statistics ScreenDevice Statistics Isolating Errors Ring Information Lost Frame Errors Ports EnabledNON-ISOLATING Errors Ring NumberToken Errors Frame Copied ErrorsRcvr Congestion Errors Frequency ErrorsSelecting the Device Statistics Counter Mode Setting the Refresh FieldPort Status Enable All PortsChassis Status View Screen TempOperational Setting the Enable All Ports OptionSetting the Operational/Administrative Mode Option ReturnComponent Status View Screen 11. Component Status View ScreenSnmp Tools Screen Getnext GETSET WalkCommunity Name Security Access LevelGetting and Setting OIDs Local Management Scrolling Through Mib OIDs Local Management Local Management

TRXI-42A, TRMIM-24A, TRXMIM-44A, TRXI-22A specifications

Cabletron Systems was a pioneering company in the network and telecommunications industry, renowned for their innovative networking products. Among the array of devices they developed are the TRXI-22A, TRXMIM-44A, TRMIM-24A, and TRXI-42A. These modules are designed to cater to a variety of networking needs, showcasing versatile functionalities and robust performance features.

The TRXI-22A is a multi-port interface card that seamlessly integrates with Cabletron's networking systems. With its advanced architecture, it is capable of high-speed data transmission, making it ideal for environments that demand bandwidth and low latency. The TRXI-22A supports a variety of protocols, thus ensuring compatibility with multiple network types. This module is particularly known for its efficient processing capabilities, which reduce bottlenecks in data flow, ensuring smooth communication across networks.

In parallel, the TRXMIM-44A serves as a modular interface module that enhances network scalability. Equipped with 44 ports, the TRXMIM-44A enables the connection of numerous devices, allowing for expansive network growth. Its design optimizes network configuration, ensuring a stable and consistent performance across connected devices. The module supports Ethernet, allowing it to cater to both legacy and modern networking equipment, which is essential for organizations transitioning to more advanced infrastructures without overhauling existing systems.

The TRMIM-24A module is another critical asset in Cabletron's lineup. It is known for its robust management capabilities, offering advanced monitoring tools that empower network administrators to track performance metrics effectively. The TRMIM-24A features smart diagnostics that assist in troubleshooting, providing real-time insights into network health. This functionality promotes proactive management, minimizing downtime and ensuring uninterrupted service.

Lastly, the TRXI-42A stands out for its versatility and high performance. Designed for dynamic networking environments, it supports a myriad of data formats and protocols, making it a suitable choice for diverse applications. The TRXI-42A’s architecture is capable of handling large volumes of data traffic with ease, thus enhancing overall network throughput. In addition, it boasts security features that protect against unauthorized access and malicious attacks, ensuring data integrity.

Overall, the Cabletron Systems TRXI-22A, TRXMIM-44A, TRMIM-24A, and TRXI-42A are exemplary modules that encapsulate quality, performance, and adaptability. They are built to support the ever-evolving demands of networking, providing solutions that are not only efficient but also future-proof. Their combination of high-speed capabilities, scalability, and robust management tools make them integral to any substantial networking infrastructure.