Cabletron Systems TRXI-42A, TRXI-22A, TRMIM-24A REQUIREMENTS/SPECIFICATIONS General Specifications

Page 29

REQUIREMENTS/SPECIFICATIONS

2.5GENERAL SPECIFICATIONS

The operating specifications for the TRXI are described in this section. Cabletron Systems reserves the right to change these specifications at any time without notice.

Data Buffer Memory (RAM):

4 MB (Upgradeable)

Internal Processor:

Intel 80C960CA at 16 MHz

Controller:

Texas Instruments TMS380

Static RAM:

128 KB with battery back-up

EPROM:

128 KB

FLASH MEMORY:

2 MB (Upgradeable)

POWER SUPPLY REQUIREMENTS

Note: The TRXI has a universal power supply. This unit allows you to use an input power from 85 to 264 VAC, 47-63 Hz.

The power supply has two outputs of +5 volts and +12 volts. The maximum output power is 125 watts and the minimum efficiency is 65% under all conditions of line at full load. The minimum and maximum load current from each output is shown below.

Output

Min. Load

Max. Load

Max Power

+5 Volts

1.00 Amps

15 Amps

75 Watts

+12 Volts

0.15 Amps

4 Amps

48 Watts

ENVIRONMENTAL REQUIREMENTS

 

 

 

 

Operating Temperature:

+5° to +50°C

 

Non-operating Temperature:

-30° to +90°C

 

Operating Humidity:

5 to 95% (non-condensing)

Page 2-17

Image 29
Contents Cabletron SYSTEMS, P. O. Box 5005, Rochester, NH Printed On Recycled Paper FCC Notice Exclusion of Warranty and Disclaimer of Liability Installation Contents Table of Contents IntroductionREQUIREMENTS/SPECIFICATIONS Local Management ContentsTesting and Troubleshooting Chapter Introduction Using this ManualTrxi Active Concentrator Overview Introduction Getting HelpCable Signal Polarity Trxi FeaturesSpeed Fault Protection Active TCU PortsTpim Rmon MIB Support LCD and Reset ButtonGroup Subgroup Section COM Port ApplicationsRecommended Reading Introduction Remote Network Management CapabilitiesCable Specifications Chapter REQUIREMENTS/SPECIFICATIONSFrequency Impedance Attenuation Attenuation and ImpedanceUTP Cable Type Maximum Lobe Length Mbps Maximum Lobe LengthsType 3 Media Filters Maximum Number of StationsREQUIREMENTS/SPECIFICATIONS Maximum Trunk Lengths STP Cable Type Ring Speed MbpsMixed Cable Types SolutionFiber Optic Budget Multimode Fiber Optic Cable Specifications for the TPIM-F2Cable Type Attenuation Maximum Drive Distance Single Mode Fiber Optic Cable Specifications for the TPIM-F3 Noise TemperatureCrosstalk REQUIREMENTS/SPECIFICATIONS Console REQUIREMENTS/SPECIFICATIONS COM 1/COM 2 Port SpecificationsModem UPSTPIM-T1 REQUIREMENTS/SPECIFICATIONS Tpim SpecificationsTPIM-T4 REQUIREMENTS/SPECIFICATIONS TPIM-T2Value Case Budget REQUIREMENTS/SPECIFICATIONS TPIM-F2Parameter Typical Worst Worst Case Typical REQUIREMENTS/SPECIFICATIONS TPIM-F3 Parameter Typical Minimum Maximum Power Supply Requirements REQUIREMENTS/SPECIFICATIONS General SpecificationsOutput Min. Load Max. Load Max Power Environmental RequirementsPhysical REQUIREMENTS/SPECIFICATIONS SafetyService Attaching the Strain Relief Bracket Unpacking the TrxiAttaching the Strain Relief Installing the TrxiRack Mounting the Trxi Installing the Trxi in the RackWall Mounting the Trxi Free-Standing Installation Ring Speed Switch Settings Installation Setting the Ring Speed SwitchInstallation Setting the Nvram Switch Connecting the Network Lobe Port Cabling Installation Connecting the Trxi to the Power SourceConfiguration Examples for TRXI-24A and TRXI-44A LNK TPIM-T4 Installation Installing the Tpim RI/RO Modules Top View Setting the TPIM’s Phantom Switch and RI/RO Switch12. Installing a Tpim Installing a Tpim to the TrxiConnecting a Twisted Pair Segment to the TPIM-T1 Connecting a Twisted Pair Segment to the TPIM-T2 or TPIM-T4 Installation LNK Finishing the Installation Checking the Installation Chapter Testing and TroubleshootingTRXI-24ATOKEN Ring HUB with Lanview Using Lanview LEDsLCD Testing and Troubleshooting Using the LCD DisplayDisplayed Message Comments Static System MessagesDisplayed Messages Comments Alarm MessagesNormal Unsaved Initialization Messages Failure or Error MessagesUnsaved Initialization Messages Displayed Message Saved System MessagesChapter Local Management Attaching the Management Terminal Local Management Management Terminal RequirementsDisplay Setup Setting the Management Terminal Setup ParametersGeneral Setup SetupRJ45 COM 2 Port Modem Cable Configuration and SetupTrxi Local Management Local Management Accessing Local ManagementMain Menu Local Management Using Local ManagementExiting Your Local Management Session Selecting a Menu OptionExiting a Local Management Screen System Date System Level ScreenSystem Time IP AddressCOM 1 Application Setting the System DateCOM 2 Application Clear All NvramSetting the IP Address Setting the System TimeSetting the Subnet Mask Setting the Enable Beacon Recovery Field Setting the Clear All Nvram FieldSnmp Community Names Screen Component Name AccessCommunity Name Editing the Community Name FieldSnmp Traps Screen Enable TrapsTrap Destination Trap Community NameSetting Snmp Traps Ring Security Screen Stn Edit Security ModeStation Address Nextscreen SAVE/EXECUTEPreviousscreen ReturnAdding Stations to the Station Address Allowed List Building the Allowed ListDeleting Stations from the Station Address Allowed List Changing the Ring Security ModeInterface Device Statistics ScreenDevice Statistics Isolating Errors Ring Information NON-ISOLATING Errors Ports EnabledLost Frame Errors Ring NumberRcvr Congestion Errors Frame Copied ErrorsToken Errors Frequency ErrorsSetting the Refresh Field Selecting the Device Statistics Counter ModeChassis Status View Screen Enable All PortsPort Status TempSetting the Operational/Administrative Mode Option Setting the Enable All Ports OptionOperational Return11. Component Status View Screen Component Status View ScreenSnmp Tools Screen SET GETGetnext WalkCommunity Name Security Access LevelGetting and Setting OIDs Local Management Scrolling Through Mib OIDs Local Management Local Management

TRXI-42A, TRMIM-24A, TRXMIM-44A, TRXI-22A specifications

Cabletron Systems was a pioneering company in the network and telecommunications industry, renowned for their innovative networking products. Among the array of devices they developed are the TRXI-22A, TRXMIM-44A, TRMIM-24A, and TRXI-42A. These modules are designed to cater to a variety of networking needs, showcasing versatile functionalities and robust performance features.

The TRXI-22A is a multi-port interface card that seamlessly integrates with Cabletron's networking systems. With its advanced architecture, it is capable of high-speed data transmission, making it ideal for environments that demand bandwidth and low latency. The TRXI-22A supports a variety of protocols, thus ensuring compatibility with multiple network types. This module is particularly known for its efficient processing capabilities, which reduce bottlenecks in data flow, ensuring smooth communication across networks.

In parallel, the TRXMIM-44A serves as a modular interface module that enhances network scalability. Equipped with 44 ports, the TRXMIM-44A enables the connection of numerous devices, allowing for expansive network growth. Its design optimizes network configuration, ensuring a stable and consistent performance across connected devices. The module supports Ethernet, allowing it to cater to both legacy and modern networking equipment, which is essential for organizations transitioning to more advanced infrastructures without overhauling existing systems.

The TRMIM-24A module is another critical asset in Cabletron's lineup. It is known for its robust management capabilities, offering advanced monitoring tools that empower network administrators to track performance metrics effectively. The TRMIM-24A features smart diagnostics that assist in troubleshooting, providing real-time insights into network health. This functionality promotes proactive management, minimizing downtime and ensuring uninterrupted service.

Lastly, the TRXI-42A stands out for its versatility and high performance. Designed for dynamic networking environments, it supports a myriad of data formats and protocols, making it a suitable choice for diverse applications. The TRXI-42A’s architecture is capable of handling large volumes of data traffic with ease, thus enhancing overall network throughput. In addition, it boasts security features that protect against unauthorized access and malicious attacks, ensuring data integrity.

Overall, the Cabletron Systems TRXI-22A, TRXMIM-44A, TRMIM-24A, and TRXI-42A are exemplary modules that encapsulate quality, performance, and adaptability. They are built to support the ever-evolving demands of networking, providing solutions that are not only efficient but also future-proof. Their combination of high-speed capabilities, scalability, and robust management tools make them integral to any substantial networking infrastructure.