Cabletron Systems SEHI-22FL manual Community Name Table Screen

Page 57

Chapter 7: Local Management

7.5THE COMMUNITY NAME TABLE SCREEN

To access the Community Name Table screen from the Feature Selection screen, use the arrow keys to highlight the Community Name Table option, then press ENTER or F6. The Community Name Table screen shown in Figure 7-4 appears.

SEHI LOCAL MANAGEMENT

Cabletron SEHI Revision X.XX.XX

COMMUNITY NAME TABLE

 

 

COMMUNITY NAME

 

ACCESS

 

 

 

 

 

 

 

 

 

 

 

PUBLIC

 

BASIC-READ

 

 

 

 

PUBLIC

 

READ-ONLY

 

 

 

 

PUBLIC

 

READ-WRITE

 

 

 

 

PUBLIC

 

SUPER-USER

 

 

 

SAVE

IP TABLE

TRAP TABLE

SNMP TOOLS

RETURN

 

F6

F7

F8

F9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1490_23

Figure 7-4 Community Name Table Screen

Community names are set through the Community Name Table option. Community names are passwords to Local Management and are agents of security control to the SEHI. SEHI access is controlled by establishing up to four different levels of security authorization: Basic-Read, Read-Only, Read-Write, and Super-User.

With Super-User access, the user changes the existing passwords by changing the community names. Only the community name assigned Super-User access has full management privileges.

The following sections explain each field on the Community Name Table screen and provides instructions on how to change them.

COMMUNITY NAME

Displays the user-defined name through which a user can access Local Management for the SEHI. Any community name assigned here acts as a password to Local Management.

7-8

SEHI User’s Guide

Image 57
Contents SEHI-22FL Intelligent Stackable HUB USER’S Guide Sehi User’s Guide FCC Notice Cabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights Contents Contents Sehi User’s Guide Vii Chapter Introduction Using this ManualFollowing conventions are used throughout this document Document ConventionsRelated Manuals Getting HelpSEHI-22FL Chapter Sehi Features and OptionsSehi Overview Sehi FeaturesRemote Network Management Capabilities Stackable CapabilitiesEpim Optional FeaturesCable Specifications Chapter Installation Requirements Specifications2 10BASE-FL Fiber Optic Network Requirements HubSTACK Interconnect Cable Requirements3 10BASE-T UTP and STP Cable Specifications SEHI-22FL Network Ports Network Port SpecificationsTransceiver Requirements COM Port RequirementsFlash Memory Operating SpecificationsPower Supply Requirements Physical Specifications Environmental RequirementsAgency Approvals Unpacking the Sehi Chapter InstallationInstalling the Sehi PRE-INSTALLATION TestTabletop or Shelf Installation Tabletop or Shelf InstallationAttaching the Strain-Relief Bracket Rackmount InstallationRack Mounting the Sehi Inch Rack Stacking the SehiStacking the Sehi Disconnect SEH and Sehi Interconnect Cables at the OUT Port Connecting the Sehi to the Power SourceADDING/REPLACING Epims Installing an EpimChapter Connecting to the Network Connecting the Sehi to the NetworkConnecting Network Ports Connecting to the Network Connecting the Sehi to the Network EPIM-T Crossover Switch Connecting a UTP Segment to an EPIM-TConnecting a Fiber Segment to an EPIM-F1/F2/F3 Sehi User’s Guide EPIM-F1, EPIM-F2, and EPIM-F3 Connecting a Thin Coaxial Segment to an EPIM-C Connect an EPIM-A to an external network segment as follows Connecting an AUI Cable to an EPIM-AEPIM-A EPIM-X Connecting an AUI Cable to an EPIM-XFinishing the Installation Installation Checkout Chapter TroubleshootingUsing Lanview Using Lanview Using the Reset Button Setting the Nvram Switch Chapter Local Management Keyboard Conventions Function Local Management Keyboard ConventionsManagement Terminal Setup Console Cable Configuration Management Terminal Setup Parameters Sehi Local Management Accessing Local ManagementFeature Selection Screen Feature Selection ScreenCommunity Name Table Screen Community Name Table ScreenBASIC-READ Configuration Configuration ScreenDisplays the IP address of the Sehi Setting the IP Address Setting the Default Gateway Trap Table Screen Trap Table ScreenTrap Table Screen Snmp Tools Screen Snmp Tools ScreenAllows the user to retrieve MIB objects using Snmp protocol Getting Individual OIDs Viewing Multiple OIDs Device Statistics Screen Device Statistics ScreenFollowing sections describe Device Statistics screen fields This command lets the user enable the selected port Port Using the Disable Port Command Epim Specifications Appendix a Epim InformationEPIM-T EPIM-F1 and EPIM-F2 Parameter Typical Minimum Maximum EPIM-F3Figure A-4 EPIM-C EPIM-CFigure A-5 The EPIM-A and EPIM-X EPIM-A and EPIM-X AUI PortAppendix B Image File Download Using OIDsSetting UP a Unix Workstation AS a Tftp Server Standard Tftp Download Standard Tftp DownloadTable B-1 Standard Tftp Download Procedure Numerics IndexIndex-2 Sehi User’s Guide Power Supply Cord

SEHI-22FL specifications

Cabletron Systems SEHI-22FL is a robust and reliable networking device designed for use in high-performance telecommunications and data communication environments. Known for its versatility, the SEHI-22FL serves as a key component in the infrastructure of businesses that require fast, efficient, and secure data transmission.

One of the main features of the SEHI-22FL is its multi-layer switching capabilities, which enable it to operate at both Layer 2 and Layer 3 of the OSI model. This means that it can handle data switching and routing, thus providing flexibility in network design. It incorporates advanced switching technologies that facilitate high-speed data transfers, making it an ideal choice for networks that demand low latency and high throughput.

The SEHI-22FL is equipped with multiple Ethernet ports that support different speeds, including 10/100Mbps and Gigabit Ethernet options, allowing users to connect various devices seamlessly. The device supports both copper and fiber optics connections, thus ensuring adaptability to various networking scenarios. This flexibility helps network administrators to optimize network performance according to the specific requirements of their organization.

For security, the SEHI-22FL comes with built-in features that include VLAN support, which allows for network segmentation. This functionality adds an extra layer of security by isolating different parts of the network, thereby minimizing the risk of unauthorized access. Additionally, it supports features such as port security and MAC address filtering, which further enhance the security protocols of the network.

The management of the SEHI-22FL is simplified through an intuitive user interface that provides comprehensive monitoring and configuration options. Network administrators can easily access important metrics and performance statistics, thus enabling quick resolution of any issues that may arise. This is complemented by support for SNMP (Simple Network Management Protocol), allowing for remote management and monitoring capabilities.

The device is designed with reliability in mind, exhibiting features such as redundant power supplies and cooling systems to ensure uninterrupted operation even in critical environments. This makes the SEHI-22FL a trustworthy choice for businesses that cannot afford downtime.

In conclusion, Cabletron Systems SEHI-22FL stands out as a versatile and powerful networking device equipped with advanced features, robust security protocols, and reliable performance. Its ability to adapt to different networking environments makes it a valuable asset for organizations looking to enhance their telecommunications infrastructure.