Brocade Communications Systems 53-0001575-01 manual Design Guidance

Page 12

SAN Design: March 29, 2001 3:18 pm

2.7SAN BUILD ING BLOCK - MESHED FABR IC CON SISTIN G OF TWO STAR TOPOLOGIES CONNECTED BY A MESH

FIGURE 7. SAN Building Block showing expansion to 17 switch Mesh Fabric

SW

SW

 

SW

 

 

 

SW

 

 

 

SW

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

An atomic building block of 8 switches (star) for larger SANs

Design can be expanded horizontally or vertically- horizontal expansion shown above using mesh design

Redundant paths through the fabric by having at least two inter- switch links per switch

Note: nodes can be on exterior switches or on interior switches. This will enable hosts/storage to be co-located on a switch if the application/data is closely associated with the host. Or, the interior switches can be used for storage devices shared by hosts on the exterior switches, eliminating a hop in the host<--->storage connection

This basic 8 switch design with single ISL’s accommodates 104 end nodes

When merging, connect the core switches using mesh

DESIGN GUIDANCE

-Recommend use of FOS version 2.1.9g/2.2.2 or higher

-Do not exceed 17 switches in this topology

-No more than three inter-switch links per edge switch

-Maximum ports 220 (single ISL)

-Max hops 6

-Take advantage of any known locality

53-0001575-01

BROCADE Technical Note

Page: 12 of 31

Image 12
Contents SAN Fabrics Design and Best Practices Guide Design and Best Practices Guide Fabric Topologies Tier Architecture Designs Single fabric, non-resilient Approach to take to SAN design for high availability Hosts Sample Switc H Configura Tions Two Fabrics -- Simplest Redundant Fabric Configuration Extended Fabric Example Numbers above are labels for the links, see text Design Guidance Edge Two Switch Core Star SAN Design Design Criteria /TESTED AN D Supported Configurations Star Topologies Possible with 2 switch cores Three Tier Design used in Fabric Aware Testing at Brocade MUlti Tier SAN Design across an Extended Link Twenty Switch Three Tier Design also a Star configuration FOS Fabric Bring UP Valid and Invalid Configurations using Inter Switch Links ZONING/NAME Space Switch HOP Coun T SAN MAN Agement NON Public Devic ES AN D Existin G FC-AL Disk Equipmen T Brocade Technical Note Glossary Gbic Topology Copyright