Introduction to the VSC 100 • Chapter 1
Nominal level | RGBHV/RGBS | 0.7V |
| 1.0V | |
Impedance | 75 ohms |
|
Sync
Input type | Autodetect RGBHV, RGBS, RGsB |
Output type | RGBHV, RGBS |
Standards | NTSC 3.58 and PAL |
Input level | 1.5V to 5.0V |
Output level | 5.0V |
Input impedance | 75 ohms |
Output impedance | 75 ohms |
Polarity | Negative |
General
Power | 100VAC to 240VAC, 50/60 Hz, 15 watts, |
| internal, |
Temperature/humidity | Storage |
| 0% to 90%, |
| Operating +32° to +122°F (0° to +50°C) / |
| 10% to 90%, |
Rack mount | No |
Enclosure type | Metal |
Enclosure dimensions | 2.25" H x 9.00" W x 6.25" D |
| 5.72 cm H x 22.86 cm W x 15.88 cm D |
| (Add 0.5” for front panel knobs and 0.75” for |
| rear panel connectors.) |
Shipping weight | 6 lbs (2.7 kg) |
Vibration | ISTA 1A in carton |
| (International Safe Transit Association) |
Approvals | UL, CUL, CE, FCC Class A |
MTBF | 30,000 hours |
Warranty | 2 years parts and labor |
Specifications are subject to change without notice.
Included Parts:
Mac – VGA cable
Power cord _
VSC 100
Video Scan Converter
User’s Manual
2Chapter Two
Making Connections and Operating the VSC 100
Connecting the VSC 100
Output Connections
Panel Switches (Rear and Front)
Input Connections
Video Connector (Cable) Pinouts
Front Panel Controls and Indicators
Troubleshooting Tips
VSC 100 • User’s Manual • Extron |