Extron electronic MMX 32 VGA MTP setup guide Front Panel Operation, Device Control

Page 2

MMX 32 VGA MTP • Setup Guide (Continued)

Step 5 — Power

Plug the included external 12 VDC power supply into the 2-pole captive screw connector. Wire the connector as shown at right.

 

3/16”

 

(5 mm) Max.

Smooth

 

 

Ridges

A

A

Power Supply

Output Cord

Tie Wrap

2-Pole Captive Screw

Connector

Front Panel Operation

Outputs 1 and 2 — For each output press the button for the desired input (1, 2 or 3). The LED for that input lights.

NOTE: When power is applied, the LEDs light sequentially from left to right. For first time power up, the default configuration is input 1 tied to both outputs

1 and 2, the front panel is not locked, and all states are unmuted. Input 1 LEDs for output 1 and for output 2 are both lit. If this is not a first time power up, then the LEDs for the last valid input selections light.

SECTION A–A

 

PRE PEAK -

 

Step 6 — Pre-Peaking and Sync Selection

 

SYNC -

Pre-Peaking— To compensate for signal loss over long cable runs, set the DIP switch

 

ON

TRI

 

 

 

 

 

 

position (up = on, down = off) as shown in the table below:

 

 

 

 

 

 

 

 

Cable length

Signal quality at max.

Video Format

distance

 

 

 

Pre-Peak Off

Pre-Peak On

High

Variable

 

 

 

 

 

Composite,

 

 

800 ft

1000 ft

S-video,

 

 

(245 m)

(300 m)

Component

 

 

 

 

 

 

 

 

 

640 x 480

<300 ft (90 m)

>350 ft (105 m)

700 ft (215 m)

750 ft (230 m)

 

 

 

 

 

800 x 600

<300 ft (90 m)

>350 ft (105 m)

550 ft (165 m)

650 ft (200 m)

 

 

 

 

 

1024 x 760

<300 ft (90 m)

>350 ft (105 m)

500 ft (150 m)

600 ft (185 m)

 

 

 

 

 

1280 x 1024

<250 ft (75 m)

>300 ft (90 m)

350 ft (105 m)

450 ft (135 m)

 

 

 

 

 

1600 x 1200

<250 ft (75 m)

>300 ft (90 m)

300 ft (90 m)

450 ft (135 m)

 

 

 

 

 

Sync selection — To select either bi-level sync or tri-level sync on output 2, set the sync DIP switch to the desired setting (up = tri-level sync, down = bi-level sync).

Front Panel Security Lock Out (Executive Mode)

Locking the front panel protects the switcher from unwanted tampering. While the switcher is locked, the user can select inputs only through a remote device.

To lock or unlock the front panel, press the following buttons simultaneously and hold them for at least 3 seconds:

For output 1 press and hold input 1 button.

For output 2 press and hold input 3 button.

The front panel LEDs flash to indicate the front panel is locked.

 

 

OUTPUT 1

 

 

 

OUTPUT 2

 

1

2

 

3

1

2

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press and hold Input 1

Press and hold Input 3

Button for Output 1.

Button for Output 2.

System Reset

To reset the switcher to its factory settings, press and hold the input 3 button for output 1 while powering up the switcher.

Audio Switching

When you select an input, the audio and video signals from that input are routed together to the appropriate output.

Audio breakaway is possible through the Extron Simple Instruction Set (SIS) or the Extron Universal Switcher Control Program. When audio breakaway is active, the front panel input LED for the audio source flashes, while the LED of the video source lights steadily.

Device Control

Output Control

Momentarily short the rear panel Remote contact pin 1, 2, or 3 for the desired output to ground to switch to that input.

Use the +5 V port when controlling the output with an MMX 32 AAP or MMX 32 MAAP panel.

RS-232 Control

Software control via the RS-232 connection is possible using the Extron Simple Instruction Set (SIS) or the Extron Windows®-based control program. The RS-232 connector on the MMX 32 VGA MTP is a 3-pole captive screw connector.

Image 2
Contents Connect Inputs InstallationMounting Connect OutputsFront Panel Operation Device ControlSymbol definitions Control by SIS commandsCommand/response table for SIS commands Software ControlUnmute RGB Output mute