Extron electronic RS-232 setup guide Edid Minder, Grounding guidelines, Configure Edid, Peaking

Page 2

MTP 15HD RS • Setup Guide (Continued)

Grounding guidelines:

Extron MTP 15HD RS products can be adversely affected by electrostatic discharge (ESD) if they are not grounded correctly.

To prevent malfunctions or product damage, an installer can correctly ground an Extron MTP 15HD RS series product by grounding the power input port. Insert one end of the grounding wire to the negative or ground pin on the power input connector (see figure 5).

Tie the other end of the wire to and earth ground.

If you have any questions about how to ground a product in a specific application, contact an Extron technical support specialist.

7.Configure EDID.

See the EDID Minder section below for instructions on configuring EDID.

8.Adjust level and peaking.

Pre-Peak switch (transmitter) — View the image and set the Pre-Peaking switch (E). Set this switch to On (up) to compensate for long cable runs of the entire system.

Level control (receiver) — View the image and adjust the Level control (see figure 6). Full counterclockwise is minimum level.

Peaking control (receiver) — View the image and adjust the Peaking control (see figure 6). Full counterclockwise is zero peaking.

9.Adjust skew delay control (SEQ receivers). Adjust the skew delay as follows (see figure 7):

a.Zero the skew delay for red, green, and blue by using a small screwdriver to press and hold the

Select button for 3 seconds. When the red, green, and blue LEDs all turn off, release the Select button.

b.Use UTP cable test equipment or examine the displayed image to determine which video signal (red, green, or blue) is shifted furthest to the left.

c.Select the furthest left video signal by using a small screwdriver to press and release the Select button until the LED for the left-shifted color lights.

d.Slowly rotate the Delay knob clockwise until the selected color is converged.

e.If the remaining colors are left shifted, repeat steps b through d.

RGB

LEVEL PEAKING

Figure 6. Level and

Peaking

DELAY

RED

SELECTGREEN BLUE

Figure 7. Skew Delay Control

10.Mount the MTPs.

If necessary, mount the MTPs. For mounting information, see the MTP 15HD RS Series User Guide.

EDID Minder

To use factory-installed EDID information or the user-recorded EDID:

1.If you have not already done so, connect the source device to the MTP 15HD transmitter. Do not power on the source device at this time.

2.Set the front panel DIP switch (C) to the required frequency (50 or 60 Hz).

3.Set the rotary dial (D) to the required position (see the table to the right). Positions 1 through E are factory installed. Position 0 is for user-recorded EDID information. Position F passes the EDID from the display connected to the Monitor loop-through port on the transmitter back to the input.

50 Hz

EDID

 

 

SELECT

 

ON

 

 

RECORD

 

 

60 Hz

SPARE

MTP SERIES

 

 

1

2

3

4

Figure 8. MTP Transmitter Front Panel

To record EDID information from a specific monitor:

1.Turn the EDID Select dial (D) to position 0.

NOTE: The frequency DIP switch position (C) has no effect in this mode.

2.Connect a display to the Monitor connector on the transmitter.

NOTE: The MTP 15HD RS transmitter should be supplying the necessary 5 VDC to power on the display. However, to ensure that EDID is being transmitted, power on the display.

3.Press and release the recessed Record button (B) to begin the recording process. The Record LED (A) will flash red rapidly during recording, then return to solid green after recording is completed. At this time, the display can be disconnected. Connect the source device to the input connector.

4.Power on or restart the source device.

Rotary Switch

Resolution

Position

 

 

 

0

User-recorded EDID

 

 

1

800x600

 

 

2

1024x768 (default)

 

 

3

1280x720

 

 

4

1280x768

 

 

5

1280x800

 

 

6

1280x1024

 

 

7

1360x768

 

 

8

1366x768

 

 

9

1400x1050

 

 

A

1400x900

 

 

B

1600x1200

 

 

C

1680x1050

 

 

D

1920x1080

 

 

E

1920x1200

 

 

F

Local monitor pass-through

 

 

68-2205-50

2© 2013 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.comRev. B 03 13

Image 2
Contents Pre-Installation RS-232 DIP Switch InstallationEdid Minder Configure EdidAdjust level and peaking Grounding guidelines
Related manuals
Manual 1 pages 3.76 Kb Manual 1 pages 55.81 Kb

RS-232 specifications

The Extron Electronics RS-232, IR 402 is a versatile and powerful control system designed to simplify the integration of audio-visual equipment. This model stands out for its robustness and the efficiency it brings to various applications, particularly in enterprise, educational, and commercial environments.

One of the main features of the RS-232, IR 402 is its ability to facilitate serial communication over RS-232 and infrared (IR) signals. By harnessing these technologies, users can easily control a range of devices such as projectors, displays, and other AV components. The unit supports bi-directional RS-232 communication, which allows for both sending control commands and receiving feedback from connected devices, enhancing the overall functionality and user experience.

In addition to its communication capabilities, the RS-232, IR 402 boasts an extensive database of pre-configured drivers for popular AV devices. This feature significantly reduces setup time, enabling users to quickly integrate their systems without the need for extensive programming or custom solutions. Furthermore, it supports multiple protocol formats, ensuring compatibility with diverse device ecosystems.

Another standout characteristic of the RS-232, IR 402 is its intelligent power management. The device is capable of power sensing and has the ability to control power states of connected devices, ensuring efficient energy use and reducing operational costs. The integration of power management within the unit supports a more sustainable approach to AV installations.

The unit is equipped with Extron's proprietary EBUS technology, which simplifies the wiring process and enhances signal integrity over long distances. This technology ensures reliable communication and minimizes the risk of signal degradation, which is essential for maintaining high-quality AV performance.

The compact design of the RS-232, IR 402 makes it suitable for a range of installation scenarios, whether mounted in a rack or hidden away in a conference room. With its user-friendly interface and streamlined connectivity options, the RS-232, IR 402 promotes ease of use, allowing even those without a technical background to operate complex AV systems with confidence.

In summary, the Extron Electronics RS-232, IR 402 provides an ideal solution for control integration in varied AV environments. Its advanced features, robust communication capabilities, and efficient power management make it a preferred choice for system integrators and AV professionals looking to enhance their installations with reliable technology.