Extron electronic DVI 104 RX manual Screen is distorted or displays noise

Page 13

Ensure that the transmitter is firmly plugged into the source device and the receiver is firmly plugged into the output device.

Try resetting the system by unplugging and reconnecting the DVI connectors or the power jacks.

Try rebooting the computer.

Screen is distorted or displays noise

Ensure that the cable length does not exceed 1,640' (500 m).

Ensure that the cables are high quality multimode cable and are terminated with securely fitting plugs.

Ensure that the graphic resolution is correctly set (see “Setup and Operation”).

View the “Display Properties” of the source device to check the output resolution. The resolution and refresh rate must match the capabilities of the display device and must not exceed 1920 x 1200 at 60 Hz.

Try resetting the system by unplugging and reconnecting the DVI connectors or the power jacks.

DVI 104 Tx/Rx • User’s Guide

9

Image 13
Contents DVI Fiber Optic Extender DVI 104 Tx/RxPrecautions 安全须知 中文 Page Description DVI 104 Tx/RxFront panel features DVI 104 Tx/Rx, cont’d FeaturesNormal Position Adjusted Position Top panel features Rear panel featuresDVI 104 Tx/Rx, cont’d Side panel features transmitter only Bottom panel features DVI 104 Tx/Rx, cont’d Setup and Operation Extr Display does not show an image DVI 104 Tx/Rx, cont’d Trouble ShootingScreen is distorted or displays noise Video DVI 104 Tx/Rx, cont’d SpecificationsVideo input transmitter Video output receiverEMI/EMC Included parts DVI 104 Tx/Rx, cont’d PartsFiber optic cables DVI 104 Tx/Rx User’s Guide DVI 104 Tx/Rx User’s Guide Central America Extron’s WarrantyExtron Electronics. All rights reserved