Tripp Lite IBAR 12 owner manual Rackmount Installation, Wallmount/Under Counter Installation

Page 1

200112060 Isobar RM Metal Owner’s Manual 93-2028.qxd 1/3/02 2:48 PM Page 1

Owner’s Manual

Rackmount Power Strips and Isobar®

Rackmount Surge Suppressors/

Line-Noise Filters

Designed to Occupy One Standard 19 in. Rack Space

Español: p. 5 • Français: p. 11

IMPORTANT SAFETY INSTRUCTIONS. This manual contains information concerning the proper installation and use of Tripp Lite’s Rackmount Power Strips and Isobar Surge Suppressors. SAVE THESE INSTRUCTIONS.

(IBAR12, IBAR12ULTRA, RS-1215, RS-1215-RA, RS-1215-HG, RS-0615-R, RS-0615-F, DRS-1215): DO NOT exceed the MAXIMUM LOAD of 15 amps that can be drawn from each AC outlet. DO NOT exceed the MAXIMUM LOAD of 15 amps that can be drawn from all the outlets combined.

(IBAR12/20ULTRA, IBAR12-20T, RS-1215-20): DO NOT exceed the MAXIMUM LOAD of 15 amps that can be drawn from each AC outlet located on the front of the IBAR12/20ULTRA and IBAR12-20T. DO NOT exceed the MAXIMUM LOAD of 20 amps that can be drawn from each AC outlet on the RS-1215-20, or each AC outlet located on the rear of the IBAR12/20ULTRA and IBAR12-20T. DO NOT exceed the MAXIMUM LOAD of 20 amps that can be drawn from all the outlets combined.

Rackmount Installation

B

To Mount Unit in Rack: Put four user-supplied rackmount

 

screws (A) through the unit’s mounting ears (B) and into

 

the rack rails as shown. The user must determine the fitness

 

of the rackmount screws to hold the unit in the rack before

 

installation.

A

Wallmount/Under Counter Installation

 

1.Detach Mounting Ears: Unscrew the screws (A) holding the unit’s mounting ears (B) to the sides of the unit.

2.Reorient Mounting Ears: Use the screws from Step 1 (A) to reattach the mounting ears (B) to the unit as shown.

Use only the manufacturer-supplied screws or their

Step 1

equivalent (#6-32, ¼" flat head) to reattach the mounting

 

ears. The screws should be put through diagonally

 

opposite holes on the ear.

 

3. Mount Unit on Surface: Put four user-supplied screws

 

(C) or similar mounting hardware through the unit’s

Steps 2 & 3

 

mounting ears (B) and into the mounting surface as shown. The user must determine the fitness of the user- supplied mounting hardware to support the unit before mounting.

Image 1
Contents Wallmount/Under Counter Installation Rackmount InstallationIlluminated On/Off Switch All Models FeaturesDiagnostic Indicator Lights Ibar Models Only Circuit Breaker All ModelsIBAR12 IBAR12ULTRA IBAR12/20ULTRA SpecificationsUltimate Lifetime Insurance Policy Limited Lifetime WarrantyMontaje Sobre la Pared / Instalacion Bajo el Mostrador Instalacion en Bastidor o RackCharacteristicas Especificaciones Characteristicas continuaEspecificaciones continua Garantía Limitada para la Vida Útil del Equipo Page Fixation Mural/Installation Sour Un Comptoir Installation Sur BatiCommutateur « ON/OFF » Illuminé tous les modèles CaracteristiquesCaracteristiques suite RS-0615-R RS0615-F Assurance Ultime á Vie Garantie Limitee a VieTh Street Chicago, IL 60609 USA Customer Support 773

RS-1215, RS-1215-RA, IBAR 12 ULTRA, DRS-1215, RS-0615-R specifications

The Tripp Lite RS-1215-RA is a robust power distribution unit designed specifically for data centers and network environments. With its versatile features, it effectively manages and distributes power, ensuring reliable operation of critical equipment. The RS-1215-RA supports a wide range of electrical devices with an impressively designed layout that accommodates multiple configurations.

Key features of the Tripp Lite RS-1215-RA include a heavy-duty metal housing that offers durability while maintaining a lightweight profile for easy installation. The unit is equipped with 12 AC outlets that are strategically spaced for the convenient connection of large power adapters and other devices. An integrated circuit breaker provides overload protection, safeguarding connected equipment from electrical surges and ensuring safety.

The technology behind the Tripp Lite RS-0615-R enhances its performance by incorporating advanced power monitoring capabilities. This allows users to track power consumption metrics, which can be critical for optimizing energy efficiency in environments with extensive IT infrastructure. The RS-0615-R is designed to facilitate efficient energy distribution, enabling businesses to manage their power usage effectively.

Additionally, the RS0615F model offers features such as a built-in LED indicator that provides real-time status updates on power conditions, making it easier for users to identify potential issues. Its compact design and mounting capabilities allow for flexible positioning within racks or wall-mounted setups, catering to various installation requirements.

The IBAR 12 ULTRA version further elevates the standard by introducing enhanced surge protection technology that defends against spikes and dips in electrical supply. This model is ideal for mission-critical applications, where continuous uptime is essential. With a focus on safety, the IBAR 12 ULTRA complies with UL standards, ensuring that it meets rigorous safety requirements for electrical equipment.

In summary, the Tripp Lite RS-1215-RA, RS-0615-R, RS0615F, and IBAR 12 ULTRA are essential components in modern data infrastructure. Together, they provide reliable power distribution, advanced monitoring, and superior protection against electrical disturbances. Their innovative design and cutting-edge technology enable them to support various applications in growing and demanding IT environments, making them a valuable investment for any organization.