Tripp Lite APS/PV Limited Warranty, OFF/ON Switch PV Remote, LOAD LOW/MED/HIGH LEDs PV Remote

Page 2
2. OFF/ON Switch (PV Remote)

2. OFF/ON Switch (PV Remote)

Move this switch to the ON position to have your PowerVerter provide connected equipment with AC power by converting DC power from an attached battery. To prevent battery drain, leave it in the OFF position when not using connected equipment.

3. LOAD LOW/MED/HIGH LEDs (PV Remote)

These three lights show the approximate voltage demand on your PowerVerter Plus.

LEDs Illuminated

ApproximateLoad

Green

0% - 20%

Green & yellow

21%

- 40%

Yellow

41%

- 60%

Yellow & red

61%

- 80%

Red

81%

- Full

All three lights off

Inverter off

Flashing red

Overload

4. AUTO/CHARGE ONLY Switch (APS Remote)

Move this switch to the AUTO position to have the APS provide connected equipment with AC power (converted from DC power from attached batteries) in the event of an AC power outage. Move it to the CHARGE ONLY position when equipment is not in use to conserve battery power by disabling the inverter. In either position, the APS will supply AC power to connected equipment and charge connected batteries while AC input is present.

5. LINE LED (APS Remote)

This green light will turn continuously ON when the APS is receiving AC power input if the APS is set to AUTO/REMOTE and the Remote is set to AUTO. This indicates that the APS will provide power from battery backup if utility power fails. It will flash intermittently when the APS is receiving AC power input if the APS is set to AUTO/REMOTE and the Remote is set to CHARGE ONLY to warn you that the APS WILL NOT provide battery backup during AC power outages.

6. INV LED (APS Remote)

This yellow light will turn continuously ON when connected equipment is receiving battery-supplied AC power (i.e. during a power outage or when the APS is disconnected from AC input).

7. LOAD LED (APS Remote)

This red light will turn continuously ON to warn that the APS’s load is between 80% and 110% of capacity. The light will flash when the APS's inverter shuts down due to a severe overload or overheating. If this happens, turn the APS OFF, remove the overload and let the APS cool before turning it ON again.

Limited Warranty

Tripp Lite warrants its products to be free from defects in materials and workmanship for a period of one year (domestic) or 120 days (export) from the date of initial purchase. Tripp Lite’s obligation under this warranty is limited torepairingorreplacing(atitssoleoption)anysuchdefectiveproducts.Toobtainserviceunderthiswarrantyyoumust obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite service center. ProductsmustbereturnedtoTrippLiteoranauthorizedTrippLiteservicecenterwithtransportationchargesprepaid andmustbeaccompaniedbyabriefdescriptionoftheproblemencounteredandproofofdateandplaceofpurchase.This warrantydoes not applytoequipment whichhas been damaged by accident,negligenceor misapplication or hasbeen altered or modified in any way. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Somestatesdonot permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

2

Image 2
Contents APS/PV Remote Installationfor PowerVerter APS and PowerVerter Plus Models Operation4. AUTO/CHARGE ONLY Switch APS Remote Limited Warranty2. OFF/ON Switch PV Remote 3. LOAD LOW/MED/HIGH LEDs PV RemoteOperación Control Remoto para los modelos PowerVerter APS y PowerVerter PlusInstalación Manual de Operación5. Luz “LINE” línea - APS Remote Garantía LimitadaDemanda de Carga Conectada 6. Luz “INV” inversor - APS Remote