Tripp Lite Utility/ Work Truck DC-to-AC Inverters owner manual Required Configuration

Page 5

Configuration

Note: Tripp Lite recommends that users only change settings for the DIP switches and controls described below. Additional DIP switches and controls located in the unit's DIP switch panel or in other areas are preset to optimize the unit's operation. Setting these DIP switches or controls may adversely affect the unit's operation.

Required Configuration

DIP SWITCH 1

Select Battery Type—REQUIRED

Using a small tool, set the DIP switch to match the type of batteries you connect.

A4 A3 A2 A1

Battery Type

Switch Position

Gel Cell (Sealed) Battery

Up

Wet Cell (Vented) Battery

Down (factory setting)

CAUTION: The Battery Type DIP Switch setting must match the type of batteries you connect, or your batteries may be degraded or damaged over an extended period of time. See “Battery Selection,” for more information.

Optional Configuration

DIP SWITCH

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting Procedure

 

Select Equalize Battery Charge—OPTIONAL

• Move to “Equalize” (DOWN) position for three seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(For use when using auxiliary batteries. See Battery Selection section.)

• Move to “Reset” (UP) position and leave it there. This is the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This DIP Switch is momentarily engaged to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

factory default setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

begin the process of equalizing the charge state

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: Do not leave DIP switch #B3 in the down position after beginning process. Battery

 

 

 

 

 

 

 

 

of your battery’s

cells by time-limited

 

 

 

 

 

 

 

 

 

 

 

charge equalization should only be performed in strict accordance with the battery manufacturer’s

 

overcharge of all cells. This can extend the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

instructions and specifications.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

useful life of certain types of batteries; consult

 

 

 

 

 

 

 

 

 

 

 

Battery Charge

Switch Position

 

with your battery’s

manufacturer to determine if your batteries could

Reset

Up (factory setting)

benefit from this process. The charge equalization process is automatic;

Equalize

Down—momentarily

once started, it can only be stopped by removing the input power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Charger

Switch Position

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Battery Charging Amps—OPTIONAL

Low Charge Amps

Up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check specifications for your unit’s high- and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Charge Amps

Down (factory setting)

low-charging amp options. By setting on high

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

charging, your batteries will charge at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

maximum speed. By setting on low charging

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(factory setting), you lengthen the life of your

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

batteries (especially smaller ones).

 

 

Connect Remote Control—OPTIONAL

An 8-conductor telephone style receptacle on the front panel is included for use with an optional remote control module (included). The remote module allows the Inverter to be mounted in a compartment or cabinet out of sight, while operated conveniently from within the cab of your vehicle. See instructions packed with the remote control module.

Connect Battery Temperature Sensing Cable—OPTIONAL—(Select models only)

The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature. Connect the sensor cable (the cable, included, has an RJ style connector on one end and a black sensor on the other) to the RJ style jack located on the side of the Inverter labeled “Remote Temp. Sense.” With user-supplied electrical or duct tape, affix the sensor to the side of the battery below the electrolyte level. Make sure that nothing, not even tape, comes between the sensor and the side of the battery. To guard against false readings due to ambient temperature, place the sensor between batteries, if possible, or away from sources of extreme heat or cold. If the sensor cable is not used, the Inverter will charge according to its default 25º C values.

Utilize Automatic Generator Starter Capability—OPTIONAL—(Select models only) Although not typically applicable to utility/work truck situations, select Inverter models offer an RJ type modular jack on the side panel labeled “Generator Start.” If your current fleet is already equipped with generators, select Tripp Lite Utility/Work Truck Inverters provide your crews the option of quiet power for residential environments or late-night job sites. When wattage loads are within the Inverter's ratings, crews can avoid the power overkill, fuel consumption, fumes and noise of generator use.

To tie the Inverter and generator together, simply connect the generator's AC power output to the Inverter's AC input. The Inverter will automatically charge the battery when generator power is available, and generator power will automatically pass-through for use via the Inverter's GFCI receptacles or hardwire terminals (depending on model). To automatically activate the generator when battery voltage runs low, attach to vehicle generator ON/OFF switching mechanism with user-supplied cable (see Pin Configuration Diagram). Once attached, the interface will allow the Inverter to automatically switch a vehicle generator on when connected battery voltage levels are low (11.6 VDC) and switch it off when battery voltage levels are high (14.1 VDC).

5R

Image 5
Contents Work Truck DC-to-AC Inverters ContentsLimited Warranty Important Safety InstructionsBattery Connection Warnings Location WarningsOperation Feature IdentificationSwitch Modes Resetting Your Inverter to Restore AC Power Indicator LightsOptional Configuration ConfigurationRequired Configuration Select Auxiliary Battery Type if any Battery Selection optionalMatch Battery Amp-Hour Capacity to Your Application ExampleVehicular and Non-Vehicular Mounting Mounting750 & 1250 models only Model onlyVehicular Battery ConnectionAC Input/Output Connection Connection for Models with Hardwire TerminalsConnection for Models with Cords and Receptacles Dual Input/Output ModelsTroubleshooting ServiceMaintenance 11R 12R