Resistant to electrostatic discharge
Supports loads up to 700VA/450 watts
36 minutes half load runtime (with 350VA load), 14.5 minutes full load runtime (with 700VA load)
6 protected
PowerAlert unattended shutdown software available via free download from www.tripplite.com (cabling included)
Complete surge protection, line isolation and EMI/RFI noise filtering
2 year product warranty
5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace
Battery replacement door Grounding lug
Specifications
SYSTEM OVERVIEW
Voltage compatibility | 230V AC |
|
|
Frequency | 50/60 Hz |
compatibility |
|
|
|
OUTPUT |
|
Output VA | 700 |
|
|
Output watts | 450 |
|
|
Output nominal | 230V AC |
voltage |
|
|
|
Output voltage | LINE MODE: Sine wave line voltage 230V |
regulation | BATTERY MODE: PWM sine wave output 230V |
|
|
Output frequency | LINE MODE: Passes line frequency of 50Hz |
regulation | BATTERY MODE: Inverter output regulated to 50/60Hz |
|
|
Outlet quantity / type | 6 IEC C13 |
|
|
Overload protection | Resettable circuit breakers |
|
|
INPUT |
|
Maximum input amps | 3.6A / 828 watts |
|
|
Input connection type | IEC C14 inlet |
|
|
Input cord length | 6 inch dongle., 16 gauge |
|
|
Recommended | 10A 230V |
Electrical Service |
|
|
|
BATTERY |
|
Full load runtime
Half load runtime
DC system voltage
Typical battery lifespan
14.5minutes (700VA) 36 minutes (350VA)
36V DC
Battery recharge rate | |
|
|
VOLTAGE REGULATION |
|
Voltage regulation | Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to |
description | maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V |
| AC |
|
|
Overvoltage | Input voltages between 206 and 245V AC are reduced by 9% |
correction |
|
|
|
Direct pass through
Input voltages between 200 and 244V AC are passed through unchanged
Brownout correction
Input voltages between 183 and 199V AC are boosted by 10%