Tripp Lite SMX700HG Leds Alarms & Switches, Surge / Noise Suppression, Physical, Environmental

Page 3

Severe brownout correction

Input voltages between 155 and 182V AC are boosted by 21%

LEDS ALARMS & SWITCHES

Front panel LEDs

Alarms

Switches

Yes, includes 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning

3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone)

Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions

SURGE / NOISE SUPPRESSION

AC surge suppression

340 joules

 

 

AC suppression

Instantaneous

response time

 

 

 

EMI / RFI AC noise

Yes

suppression

 

 

 

PHYSICAL

 

Shipping weight (lbs)

45.4

 

 

Shipping weight (kg)

20.4

 

 

Unit weight (lbs)

42.1

 

 

Unit weight (kg)

18.9

 

 

Unit Dimensions

12.8 x 7.5 x 9

(HWD/in)

 

 

 

Unit Dimensions

32.5 x 19.1 x 22.9

(HWD/cm)

 

 

 

Material of

PVC

construction

 

 

 

Form factors

Tower

supported

 

 

 

Cooling method

Cooling via rear-exit cooling fan

 

 

Battery Access

Battery access door allows hot swap battery replacement without powering connected equipment off

 

 

ENVIRONMENTAL

 

Relative Humidity

0 to 95%, non-condensing

 

 

Storage Temperature

+5 to +122 degrees Fahrenheit

 

 

Operating

+32 to +104 degrees Fahrenheit

Temperature

 

 

 

COMMUNICATIONS

 

Network monitoring

Includes 2 built-in monitoring ports, 1-USB & 1-RS232

port

 

 

 

Software and cabling

PowerAlert UPS monitoring software is available via free download from www.tripplite.com for all common network and

included

standalone operating systems. Ships with 2 cables, 1-USB to USB & 1-DB9 to DB9

 

 

LINE / BATTERY TRANSFER

Transfer time from line power to battery mode

2-4 milliseconds

Low voltage transfer

155V

(resets to line power as voltage increases to 163V)

to battery power

 

 

 

 

 

High voltage transfer

274V

(resets to line power as voltage decreases to 266V)

to battery power

 

 

 

 

 

SPECIAL FEATURES

 

 

Cold Start

Yes, inverter can be "cold started" to enable temporary AC output during a power failure

 

 

 

Appearance

Attractive gray tower UPS

Image 3
Contents Features HighlightsDescription Output SpecificationsBattery System OverviewSurge / Noise Suppression Leds Alarms & SwitchesLine / Battery Transfer Special FeaturesCertifications WarrantyProduct Warranty Certifications