Tripp Lite SMX1500XLRT2U warranty Specifications, Output AC waveform AC mode

Page 2

installation requires 2-9USTAND accessory

Large internal batteries support a max load of 1500VA for 7 minutes and a half load of 750VA for 18 minutes

Expandable runtime with BP36V15-2U (limit 1) or with multiple BP36V42-3U rack/tower external battery packs

Maintains regulated 230V nominal output during brownouts and overvoltages from 151 to 282V

Includes 8 UPS supported outlets arranged in 3 individually controllable load banks (2 outlets per bank) that can be powered off and back on again via software interface

IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and running user-defined script commands.

Offers simultaneous monitoring by up to 2 directly-connected devices through included USB and DB9 interface ports, or the monitoring by any number of additional servers over IP with included PowerAlert monitoring software.

Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored, AC line voltage, DC battery voltage and remaining battery capacity

Emergency Power Off (EPO) interface with cable

Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for delayed or immediate reboot of connected devices

Supports Tripp Lite's WatchDog software application to restore operation to locked equipment through soft reboot of application, OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications (requires optional WATCHDOGSW)

Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter

Emergency Power Off (EPO) interface with cable

Multi-function audible alarms and set of 5 front panel LEDs

Network-grade AC surge suppression

Attractive all-black color scheme

UPS battery set ships fully assembled, no time consuming connection of internal batteries by user is necessary

Specifications

OUTPUT

Output Volt Amp Capacity (VA)

Output kVA capacity (kVA)

Output Watt Capacity (watts)

Output kW capacity

Output power factor

Nominal Output Voltage(s) Supported

Nominal Voltage details

Frequency compatibility

Output voltage regulation (line mode)

Output voltage regulation (Battery mode)

Built-in UPS output receptacles

Included output power cables

Built-in controllable switched load banks

Output AC waveform (AC mode)

1500

1.5

1000

1

0.7

230V

230v nominal inverter output voltage

50 / 60 Hz

-17%, +8%

+/- 5%

8 C13 outlet(s)

Includes 2 C13 to C14 output power cables

Three switchable two-outlet C13 load banks

Sine wave

Image 2
Contents Description FeaturesHighlights Output SpecificationsOutput AC waveform AC mode Input BatteryLeds Alarms & Switches Voltage RegulationPhysical UPS Shipping dimensions height x width x depth / cmEMI / RFI AC noise suppression Secondary form factorRelated Items Dcatv DNET1 DTEL2 Envirosense PDU12IEC Snmpwebcard
Related manuals
Manual 48 pages 49.54 Kb Manual 2 pages 41.47 Kb