Input connection type
Input cord length
Recommended Electrical Service
Maximum input amps / watts
BATTERY
DC INPUT: 175A Anderson DC connector. AC INPUT: NEMA
DC INPUT: 175A Anderson DC connector at the end of a 1 ft. 1/0 gauge color coded red/black cable. User supplies DC
input cabling for use with Anderson connector. AC INPUT: attached 3 ft. AC line cord with
DC INPUT: Requires 12VDC input source capable of delivering 127A for the required duration (when used at full continuous capacity - DC requirements increase during
DC INPUT: Full continuous load - 127A at 12VDC. AC INPUT: 32 amps at 120VAC with full inverter and charger load (11 A max
Expandable battery runtime
DC system voltage
Battery recharge rate
Runtime is expandable with any number of user supplied wet or gel type batteries
12V
14A/55A (selectable)
LEDS ALARMS & SWITCHES
Front panel LEDs
Switches
Set of 6 LEDs offer continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences.
3 position on/off/remote switch enables simple on/off power control plus "auto/remote" setting that enables distant on/off control of the inverter system when used in conjunction with included External switch for wired remote control of APS unit APSRM4 ac
SURGE / NOISE SUPPRESSION
AC surge | 760 joules AC surge suppression included |
suppression |
|
|
|
PHYSICAL |
|
Shipping weight (lbs) | 24.8 |
|
|
Shipping weight (kg) | 11.2 |
|
|
Shipping | 12.5 x 11 x 10.75 |
Dimensions (HWD/in) |
|
|
|
Shipping | 31.8 x 27.9 x 27.3 |
Dimensions |
|
(HWD/cm) |
|
|
|
Unit weight (lbs) | 23.2 |
|
|
Unit weight (kg) | 10.5 |
|
|
Unit Dimensions | 7 x 8.75 x 9 |
(HWD/in) |
|
|
|
Unit Dimensions | 17.8 x 22.2 x 22.9 |
(HWD/cm) |
|
|
|
Material of | Polycarbonate |
construction |
|
|
|
Form factors | Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting |
supported | information) |
|
|
Cooling method | |
|
|
Style | |
|
|
ENVIRONMENTAL |
|
Relative Humidity | |
|
|
LINE / BATTERY TRANSFER
Transfer time from line power to battery mode
Low voltage transfer to battery power
16.6milliseconds (typical - compatible with many computers - verify transfer time compatibility of loads for UPS applications)
In AC "auto" mode, inverter/charger switches to battery mode as line voltage drops to 75V (user adjustable to 85, 95, 105V - see manual)