Tripp Lite 93-1911 warranty Specifications Hardwired Models

Page 15

Specifications (Hardwired Models)

HARDWIRED MODELS:

APS 2012

APS2424

Weight:

38.0 lbs.

41.0 lbs.

INVERTER

 

 

Continuous power (@ 20° C):

2000 W

2400 W

Surge power (5 seconds):

4000 W

4800 W

Efficiency (Full Load):

90%

90%

Minimum DC Fuse Rating:

500A

300A

DC Input Current @ Nominal V DC

 

 

Full Load

192 A

112 A

No Load

2.5 A*

1.5 A*

Nominal Input Volts:

12 VDC

24 VDC

DC Input Voltage Range:

10-15 VDC

20-30 VDC

Nominal Output Volts:

120 VAC ±5%

120 VAC ±5%

Nominal Output Frequency:

60 Hz ±.3%

60 Hz ±.3%

BATTERY CHARGER

 

 

Charging Capacity DC:

60 A

30 A

Maximum Cable Length

1 ft.

3 ft.

Acceptance Volts VDC:

Selectable

Selectable

 

14.4 V**/14.2 V Wet**/Gel

28.8 V**/28.4 V Wet**/Gel

Float Volts VDC (w/gel):

13.3 V (13.6 V)

26.6 V (27.2 V)

Input Voltage AC:

120 V

120 V

Input Current AC:

16 A

16 A

LINE VAC OPERATION

 

 

Minimum Input AC Volts:

Selectable 75**,85, 95, or 105 VAC Selectable 75**,85, 95, or 105 VAC

Maximum Input AC Volts

 

 

(Continuous, Charger at Maximum):

Selectable 135** or 145 VAC

Selectable 135** or 145 VAC

Maximum Input Current

 

 

(Continuous, Charger at Maximum):

32 A

36 A

Input Frequency:

60 Hz ±10%

60 Hz ±10%

Maximum Output AC (Continuous)

16.7 A

20 A

Automatic Transfer Time:

4-6 ms

4-6 ms

HARDWIRED MODELS (Cont.):

APS 2448

APS3636VR

Weight:

38.0 lbs.

56.9 lbs.

INVERTER

 

 

 

Continuous power (@ 20° C):

2400 W

3600 W

Surge power (5 seconds):

4800 W

7200 W

Efficiency (Full Load):

90%

89%

Minimum DC Fuse Rating:

300A

300A

DC Input Current @ Nominal V DC

 

 

 

Full Load

56

A

114 A

No Load

1.5 A*

1.7 A*

Nominal Input Volts:

48 VDC

36 VDC

DC Input Voltage Range:

40-60 VDC

30-45 VDC

Nominal Output Volts:

120 VAC ±5%

120 VAC ±5%

Nominal Output Frequency:

60

Hz ±.3%

60 Hz ±.3%

BATTERY CHARGER

 

 

 

Charging Capacity DC:

15

A

30 A

Maximum Cable Length

12 ft.

4.5 ft.

Acceptance Volts VDC:

Selectable

Selectable

 

57.6 V**/56.8 V Wet**/Gel

43.2 V**/42.6 V Wet**/Gel

Float Volts VDC (w/gel):

53.2 V (54.4 V)

39.9 V (40.8 V)

Input Voltage AC:

120 V

120 V

Input Current AC:

16

A

24 A

LINE VAC OPERATION

 

 

 

Minimum Input AC Volts:

Selectable 75**,85, 95, or 105 VAC Selectable 75**,85, 95, or 105 VAC

Maximum Input AC Volts

 

 

 

(Continuous, Charger at Maximum):

Selectable 135** or 145 VAC

Selectable 135** or 145 VAC

Maximum Input Current

 

 

 

(Continuous, Charger at Maximum):

33

A

54 A***

Input Frequency:

60

Hz ±10%

60 Hz ±10%

Maximum Output AC (Continuous)

20

A

30 A

Automatic Transfer Time:

4-6 ms

4-6 ms

*Load sense can reduce this to 1/30 of the listed current. **Factory default setting. ***When AVR is boosting incoming current.

15

Image 15
Contents Configuration & Connection p APS PowerVerterIntroduction Frequency-Controlled Inverter Output Advanced, 3-Stage Battery ChargerVoltage Regulation Select models only Load Sharing Select models onlyEquipment Connection Warnings SafetyBattery Connection Warnings APS Location WarningsConfiguration Equalize Battery Charge Disable Battery Charger APS 2448 onlyLoad Sharing Selecting Battery Amp Hour Capacity Battery SelectionLimit Battery Charger APS 1012 and APS 2012 only Selecting Battery TypeMounting Optional Battery Connection StandardBattery Connection DC Vehicular See Diagram 2, pAC Input Electrical Connection Hardwired Electrical ConnectionsSet Operating Mode Switch AC ConnectionSwitches, Indicator Lights Other Features SwitchesIndicator Lights Other Features Service Maintenance & ServiceLimited Warranty MaintenanceSymptom Problems Corrections TroubleshootingInverter Specifications Corded ModelsSpecifications Hardwired Models Diagrams/Esquemas APS 12V Battery HI/MED/LO Th Street Chicago, IL 60609 USA Customer Support 773