Tripp Lite OmniSmart & SmartPro USB Two symbols are used on the label ~ AC Voltage DC Voltage

Page 8

Specifications

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

SmartPro® USB UPS Systems

Model:

SMART500USB

SMART550USB

SMART700USB

Series:

163620U1

AGSM500USBKJR6

AGOM1000USBKSR6

Input Voltage/Frequency:

120V/60 Hz

120V/60 Hz

120V/60 Hz

On-Line Input Voltage Range:

83 - 147 volts

83 - 147 volts

83 - 147 volts

Output Capacity (VA/Watts):

500/300

550/300

700/450

Battery Runtime (Half Load/Full Load) Minutes:

17/5

17/5

20/6

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

2-4 hrs.

Approvals:

UL, cUL, NOM, FCC-B

UL, cUL, NOM, FCC-B

UL, cUL, NOM, FCC-B

Tel/Fax/Data Protection:

1-line tel/DSL

1-line tel/DSL

1-line tel/DSL/Ethernet

 

 

 

 

OmniSmartUPS Systems

Model:

OMNISMART500

OMNISMART700

OMNISMART850

OMNISMART1000VS

Series:

AGSM500USBKJR6

AGOM700USBKSR61

AGOM1050PJR61

AGOM1000USBKSR6

Input Voltage/Frequency:

120V/60 Hz

120V/60 Hz

120V/60 Hz

120V/60 Hz

On-Line Input Voltage Range:

75 - 147 volts

75 - 147 volts

75 - 147 volts

83 - 147 volts

Output Capacity (VA/Watts):

500/300

700/425

850/600

1000/500

Battery Runtime (Half Load/Full Load) Minutes:

17/5

22/7

26/9

17/5

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

2-4 hrs.

2-4 hrs.

Approvals:

UL, cUL, NOM, FCC-B

UL, cUL, NOM, FCC-B

UL, cUL, NOM, FCC-B

UL, cUL, NOM, FCC-B

Tel/Fax/Data Protection:

1-line tel/DSL

1-line tel/DSL/Ethernet

None

1-line tel/DSL

Model:

OMNISMART1050

OMNISMART1400

Series:

AGOM1050PJR61

AGOM1400PSR61

Input Voltage/Frequency:

120V/60 Hz

120V/60 Hz

On-Line Input Voltage Range:

75 - 147 volts

75 - 147 volts

Output Capacity (VA/Watts):

1050/705

1400/940

Battery Runtime (Half Load/Full Load) Minutes:

23/7

24/8

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

Approvals:

UL, cUL, NOM, FCC-B

UL, cUL, NOM, FCC-B

Tel/Fax/Data Protection:

None

None

 

 

 

ALL UNITS: Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB at 1MHz); AC Protection Modes (H to N, H to G, N to G).

FCC RADIO/TV INTERFERENCE NOTICE: Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference using one or more of the following measures: reorient or relocate the receiving antenna; increase the separation between the equipment and receiver; connect the equipment into an outlet on a circuit different from that which the receiver is connected; consult the dealer or an experienced radio/television technician for help. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

CONSUMER INFORMATION AND FCC REQUIREMENTS (U.S. only):

1.This equipment complies with Part 68 of the FCC rules. On the top or bottom of this equipment is a label that contains, among other information, the FCC registration number for this equipment. If requested, provide this information to your telephone company.

2.If your Fax/Modem Protector causes harm to the telephone network, the telephone company may temporarily discontinue your service. If possible, they will notify you in advance. But if advance notice isn't practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC.

3.Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of your equipment. If they do, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.

4.If you experience trouble with this Fax/Modem Protector, please contact Tripp Lite Customer Support, 1111 W. 35th Street, Chicago, Illinois 60609; Phone (773) 869-1234 for repair/warranty information. The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure that the equipment is not malfunctioning.

5.This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. (Contact your state public utility commission or corporation for information.)

EQUIPMENT ATTACHMENT LIMITATIONS (Models with the Industry Canada label in Canada only): NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets the telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that the compliance with the above conditions might not prevent degradation of service in some situations.

Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

Note on Labeling

Two symbols are used on the label.

V~ : AC Voltage

V : DC Voltage

8

Image 8
Contents OmniSmart & SmartPro USB Battery Warnings UPS Location WarningsUPS Connection Warnings Equipment Connection WarningsSelect UPS Operating Mode Connect your UPS to An electrical outletButtons Phone Line/Network Line Surge SuppressionUSB Communications Charge only Mode Disables battery backup. UPS Indicator Lights Other UPS FeaturesService StorageTwo symbols are used on the label ~ AC Voltage DC Voltage 200306109 93-2141EN