Tripp Lite PDUMH20AT, PDUMH15AT owner manual Important Safety Instructions

Page 2

Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the installation, operation, and storage of this product. Failure to heed these instructions and warnings will void the product warranty.

The PDU provides convenient multiple outlets, but it DOES NOT provide surge or line noise protection for connected equipment.

The PDU is designed for indoor use only in a controlled environment away from excess moisture, temperature extremes, conductive contaminants, dust or direct sunlight.

Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that eliminate the connection to ground.

The power requirement for each piece of equipment connected to the PDU must not exceed the individual outlet’s load rating.

The total power requirement for equipment connected to the PDU must not exceed the maximum load rating for the PDU.

Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable parts inside.

Do not attempt to modify the PDU, including the input plugs and power cables.

Do not attempt to use the PDU if any part of it becomes damaged.

Do not attempt to mount the PDU to an insecure or unstable surface.

Never attempt to install electrical equipment during a thunderstorm.

Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.

2

Image 2
Contents PDUMH15AT PDUMH20AT Th Street Chicago, IL 60609 USAImportant Safety Instructions Connecting the PDU Mounting the PDUPDUMH15AT Connect Equipment to PDU. Do not exceed Features Preferred Configuration Automatic Transfer Switch Source SelectionAutomatic Transfer Switch Quick Test Limited Warranty Manual del propietario Instrucciones de seguridad importantes Guarde Estas InstruccionesMontaje de la PDU Conexión de la PDUInstalación continuación Conexión de la PDU continuaciónConecte el equipo a la PDU. No exceda la Capacidad de carga de la PDU. La corrienteCaracterísticas continuación Aceptable Operación mejorada Configuración y operación continuaciónPrueba rápida Garantía Limitada Manuel du propriétaire Importantes consignes de sécurité Conserver CES DirectivesMontage de lunité de distribution dalimentation PDU Connexion de lunité de distribution dalimentation PDUInstallation suite Connexion de lunité de distribution dalimentation PDU suiteConnecter léquipement à la PDU. Ne pas Dépasser la capacité de charge de la PDUCaractéristiques suite Choix de source de commutateur de transfert automatique Commutateur de transfert automatiqueConfiguration et fonctionnement suite Garantie Limitée 200706235

PDUMH15AT, PDUMH20AT specifications

Tripp Lite is renowned for its high-quality power distribution solutions, and the PDUMH20AT and PDUMH15AT models are prime examples of their innovative offerings. These power distribution units (PDUs) are designed to provide reliable power management and distribution in data centers, server rooms, and other critical environments.

The PDUMH20AT and PDUMH15AT come with several key features that enhance their functionality. Both models feature a compact design that allows for easy installation in rack enclosures or on standard server racks. The PDUMH20AT supports 20 outlets while the PDUMH15AT offers 15 outlets, providing ample power connectivity for various devices.

One of the most significant advantages of these PDUs is their versatility. They are equipped with multiple NEMA outlets, catering to a wide array of plug styles, which means they can accommodate different types of equipment without compatibility issues. Additionally, these units are built with a 10-foot power cord, ensuring flexibility in arrangement and connectivity to distant power sources.

Both models employ advanced surge protection to safeguard connected equipment from power surges and spikes. This feature is crucial for protecting sensitive electronic infrastructure in environments where electrical disturbances are common. Furthermore, they incorporate LED status indicators that provide real-time monitoring of the power status, ensuring users can easily assess their operational state.

The construction of the PDUMH20AT and PDUMH15AT is robust, featuring a metal housing that enhances durability while minimizing risks from environmental factors. These PDUs are built to withstand the rigors of a busy data center or server room.

In terms of installation, the PDUs come with mounting brackets, making it quick and easy to secure them in various configurations, whether vertical or horizontal. Additionally, the PDUMH series includes options for basic power distribution or more advanced features such as metering and monitoring, catering to different user needs.

Overall, Tripp Lite's PDUMH20AT and PDUMH15AT represent ideal power distribution solutions for any professional setting. With their blend of functionality, durability, and user-friendliness, these PDUs help ensure that critical systems operate smoothly and efficiently.